6235/6235i/6236i (RM-60)
Baseband Description and Troubleshooting
3. Is System clock at 19.2MHz
4. Is Sleep Clock at 32kHz
5. If all the above checks pass, then check whether terminal is jammed or a flash
fault exists.
R2206
R2203
Sleep Clock
Terminal in Local Mode Test
Check the following points, to see if terminal is in local mode (see
1. Is the BSI line at X2000?
2. Is the BSI line at R2203?
3. Is the BSI line at R2206?
4. Is Sleep Clock at 32kHz?
5. Is System Clock at 19.2kHz
Page 44
Figure 47: Test Points when current too high
©2005 Nokia Corporation
GND
BSI
System Clock
Figure
Company Confidential
X2000
VBAT
47):
Issue 1 04/2005