Clock Distribution; Rfclk (19.2 Mhz Analog) - Nokia RH-17 Series Troubleshooting - Bb

Transceivers
Hide thumbs Also See for RH-17 Series:
Table of Contents

Advertisement

RH-17
Troubleshooting — BB
Maximum
Regulator
current [mA]
VR1A
10
VR1B
10
VR2
100
VR3
20
VR4
50
VR5
50
VR6
50
VR7
45
A charge pump used by VR1A is constructed around UEM. The charge pump works with
Cbus (1.2 MHz Clk) and gives a 4.75 V regulated output voltage to RF.

Clock Distribution

RFClk (19.2 MHz Analog)

The main clock signal for the baseband is generated from the voltage and temperature
controlled crystal oscillator VCTCXO (G501). This 19.2 MHz clock signal is generated at
the RF and fed to RFCLK pin of UPP.
Page 12
Table 2: RH-17 RF Regulators
Vout [V]
4.75
4.75
2.78
2.78
2.78
2.78
2.78
2.78
Nokia Corporation
CCS Technical Documentation
Notes
Enabled when the receiver is on
Enabled when the transmitter is on
Enabled when the transmitter is on
Enabled when SleepX is high
Enabled when the receiver is on
Enabled when the receiver is on
Enabled when the transmitter is on
Enabled when the receiver is on
Confidential
Issue 1 04/2003

Advertisement

Table of Contents
loading

Table of Contents