User Interface; Lcd Module - Nokia RH-6 Series Baseband Description & Troubleshooting

Table of Contents

Advertisement

CCS Technical Documentation

User Interface

LCD module

Maxwell is using a 130 * 130 dot LCD display with 4096 colors. The illumination is inte-
grated into the LCD module.
Baseband LCD interface
The LCD display is connected to the transceiver PWB by 10-pin board-to-board connec-
tor.
DC characteristics
Display is using 3-wire serial interface. Signals for LCD panel are shown in table below.
The chip-select XCS (active low) enables and disables the serial interface. RESX (active
low) is external reset signal. The SCL is serial data clock. SI data-length is 8 bits + D/C-
bit. First bit is D/C-bit which indicates the status of following 8 bit data. In case of com-
mand data D/C-bit is low ('0'). VDDI is logic voltage supply for the display. VDD is supply
voltage for high voltage generation. GND is system ground for display.
Pin
Signal
Interface
No
name
1
VDDI
VIO
2
RESX
GENIO(4) H: 0.7xVDD
3
SI
LCDUI(1) H: 0.7xVDDI
4
SCL
LCDUI(0) H: 0.7xVDDI
5
XCS
LCDUI(2) H: 0.7XVDDI
Issue 1 10/2003
Company Confidential
1
Figure 8: LCD connector
Table 8: LCD Interface DC Characteristics
Min
Typical
1.7
1.8
-
0.8
-
0.8
L: 0
L: 0
L: 0
L: 0
© 2003 Nokia Corporation.
6 - BB Description & Troubleshooting
Max
Unit
VDD
V
Logic voltage supply
1.2
µΑ
Logical supply current in full mode
1.2
µΑ
Logical supply current in partial mode
H: VDDI
V
Reset
L: 0.3xVDDI
(active low)
H: VDDI
V
Serial input
L: 0.3xVDDI
H: VDDI
V
Serial input clock
L: 0.3xVDDI
6.5
MHz Serial data clock speed
H: VDDI
V
Chip select
L: 0.3xVDDI
(Active low)