ELECTRICAL
MODEL
VOLTS
H-706
208
H-706
240
H-706EU
220-240
H-636
208
H-636
240
CUTOUT DETAILS
1 1/2
13 3/4
(349)
2 13/16
12 3/4
(324)
CLEARANCES
SUGGESTED CLEARANCE FROM
UNIT TO THE NEAREST SURFACE
BACK
SIDE
BOTTOM
1
2
(25)
(51)
(229)

INSTALLATION INSTRUCTIONS

UNIT MUST BE INSTALLED IN AN ALL METAL COUNTER
THE INSTALLATION OF RECOGNIZED COMPONENT UNITS REQUIRES
ADDITIONAL EVALUATIONS TO UNDERWRITERS LABORATORIES
STANDARDS.
INSTALLER MUST MEET CONDITIONS OF ACCEPTABILITY OUTLINED
BELOW UPON INSTALLATION:
1. This appliance must be installed in an all metal counter with suitable
wiring and control enclosures conforming to national and local electrical
codes.
2. Electrical component temperatures, including wiring, within and
surrounding the appliance must be monitored in the end use installation
for suitability.
3. Electrical grounding of all dead metal parts must be reliably
connected to the grounding means of the appliance and must comply with
requirements outlined in the appropriate Underwriters Laboratories Inc.
classification, national and local electrical codes.
4. Increased clearances are required if storage of combustible materials
is in close proximity to this appliance.
5. Unit shall be accessible for servicing from bottom.
6. The name/rating plate information shall be accessible.
AMPS PER LINE 3 PHASE
WATTS
L1
L2
3000
12.5
7.2
4000
14.4
8.3
4000
-
-
3900
16.3
9.4
5200
18.8
10.8
22 7/16
(570)
(38)
(71)
4 7/8
(124)
FRONT
9
1
(25)
WELLS/BLOOMFIELD * VERDI, NV
AMPS
FIELD WIRING GAUGE
SINGLE
L3
3 PHASE
PHASE
7.2
14.4
14 AWG Cu
8.3
16.7
14 AWG Cu
-
16.7
-
9.4
18.8
14 AWG Cu
10.8
21.7
14 AWG Cu
PRODUCT DIMENSIONS
23 1/2
(597)
14 3/4
(375)
6 1/4
(159)
14 1/8
(359)
HOTPLATE FLANGE
GASKET
COUNTERTOP
TO FABRICATE AND INSTALL:
1. Lay out cutout dimensions on countertop and control
apron as shown in cutout details.
2. Cut and/or drill holes as required in countertop and apron.
3. Place gasket on underside of flange (see detail above).
4. Locate Hotplate over counter to cutout. Pass control panel
through countertop cutout and bring it through control cutout
on apron. Seat Hotplate on countertop.
5. From underneath, insert screwdriver into slots on patented
Wellslok frame and twist ears counterclockwise to secure
flange tightly to countertop.
6. Mount control box to apron using screws supplied. Connect
service leads to terminal block located at right of control
box. Mount front panel to control box.
NOTE: INSTALLATION MUST MEET LOCAL AND NATIONAL
ELECTRICAL CODES.
INSTALLATION INSTRUCTIONS
BUILT-IN HOTPLATES
MODEL H-706, H-636
TEMP.
RATING
1 PHASE
10
90°C
10
90°C
10
90°C
10
90°C
10
90°C
4 1/2
(114)
METAL SHIELD
WELLSLOK
SCREWDRIVER
37118-1 REV (-)
INCHES
(MM)
9
(229)