Remote Control Wiring - Rheem Raypak 268A Installation And Operation Manual

Atmospheric gas-fired pool and spa heater
Hide thumbs Also See for Raypak 268A:
Table of Contents

Advertisement

Remote Control Installation and Operation
A
CAUTION: Before installing remote controls
to the heaters, read the following: The heater is
remote-ready in most cases. The digital liquid crystal
display (LCD) shows the actual pool temperature,
operating status, and service codes. See Figure 38. The
touch pad on the control panel allows you to select the
desired pool or spa temperature. It also indicates when
a remote system is controlling the heater by displaying
Remote in the display. When connecting the heater to a
remote system, identify whether it is a two- or three-wire
remote system. Select the appropriate instruction listed
below to properly install the remote to the heater.
Remote Operation
The heaters are equipped with the ability to work with
external remote controls. The supplied 7-pin remote wiring
connector supplies power out to either a toggle switch or
the switch contacts of a third-party remote. The remote
works by either making or breaking the circuit created
by the remote wiring. Typically, a remote does not supply
power to the heater, it only provides a switching function
to turn the heater On or Off. If your remote is supplying
its own voltage to the heater, it will not work with this
heater and may damage the digital circuit board.
For operation of the heater using the onboard thermostatic
controls with a time clock.
Switch" on page 29.
Figure 38. Remote Control Menu - Remote Operation
APPROVED
See "Time Clock/Fireman's
OFF Mode
Heating in the POOL Mode
Heating in the SPA Mode
Remote Mode
UNCONTROLLED DOCUMENT IF PRINTED
Activating the Remote
To activate or deactivate the remote function:
1. Press and hold the UP and DOWN arrow buttons for
3 to 5 seconds.
The second line of the display will alternate even when the
unit is off ("No Demand").
NOTE: When in remote operation, the keypad mode and
temp buttons are disabled.
Figure 39. Remote Control Menu - Activation

Remote Control Wiring

OBSERVE PRECAUTIONS
A
CAUTION: Electrostatic Discharge (ESD) damage
can be caused by direct or indirect contact with the
wiring or circuit board. When one walks to the heater
area, an electrostatic charge accumulates on the body.
Contact of a finger allows the body to discharge, possibly
causing device damage. This damage can be limited if
the service person discharges himself, following ESD
preventive/removal practices, and holds on to the heater
enclosure for 5 seconds before proceeding.
Important Installation Notes for Remote or External
Wiring Configuration:
Remote wiring must be run in a separate conduit.
Remote wiring must not be run parallel to high voltage
lines.
For runs of under 30' (9 m), remote wiring should
have stranded conductors with a minimum of 22
AWG, 600V, cable twisting 1.5" to 2.5" (3.8 to 6.4 cm)
lay and jacketed.
For runs over 30' (9 m), the conductors should be a
minimum of 20 AWG, 600V, cable twisting 1.5" to 2.5"
(3.8 to 6.4 cm) lay that is shielded and jacketed.
Maximum cable length is 200' (61 m).
For both two- and three-wire remote systems, the
provided 7-pin wiring connector must be utilized.
NOTE: The remote wires must be connected to the
7-pin connector before the connector is plugged into the
board.
ATTENTION
ELECTROSTATIC
SENSITIVE DEVICES
27

Advertisement

Table of Contents
loading

This manual is also suitable for:

Raypak 408a

Table of Contents