FAGOR’S corporate website at, corrections in later editions. http://www.fagorautomation.com. Fagor Automation S. Coop. will not be held responsible for any · type of file: EC Declaration of Conformity · losses or damage, direct, indirect or by chance that could result from that information and it will be the user's responsibility to use it.
Notes of operating safety Product description Carefully read the following instructions before using the Auxiliary power supply. servomotor. In these instructions, the operating safety QC-APSS-15 conditions are identified by the following labels. Its main function is to generate a voltage of +24 V DC, required to feed the QC-DR-275-SS2 drive control circuits DANGER or prohibition symbol.
Page 4
The QC-DR-275-SS2 drive that comprises part of the The FAGOR QC-RPS-160-SN0 regenerative regulated · Q u e r C u s - P o w e r D r i v e S y s t e m · w i t h FA G O R ' s...
Line Interface Module. LIM 160 Dimensions The FAGOR ·Line Interface Module 160· is an adaptation Auxiliary power supply, QC-APSS-15 module (MAINS FILTER+CHOKE) between the power lines and the QC-RPS-160-SN0 regenerative power supply, supplied by FAGOR exclusively upon request. The interior contains the following: ...
Page 6
Main power supply, QC-RPS-160-SN0 Connectors 112.5 connector figure coding pin data M10x20 Tightening torque 0.4/0.5 N·m min./max. Section 2.5 mm² Screwdriver flat-head, 0.6x3.5 mm Length to strip 7 mm Tightening torque 0.5/0.6 N·m min./max. Section 1 mm² Screwdriver flat-head, 0.6x3.5 mm Length to strip 8 mm Tightening torque...
Installation Cl ear an ce s in th e e lec tr ica l ca bin et Location MANDATORY. Inside the electrical cabinet, make sure to leave a MANDATORY. clearance of at least 10 cm (3.93 inches) between the The QUERCUS system that will usually include the equipment and the top and bottom sections and the front external safety controller is identified as a fixed panel of the cabinet and any other obstacle obstructing the...
Page 8
Install the QUERCUS system as far away as Once the installation has been completed and before possible from air inputs and outputs. handling any of the terminals on the QUERCUS equipment, follow the instructions in the order below: Carry out periodic maintenance on air filters. WARNING.
Page 9
MANDATORY. MANDATORY. * note) This type of PDS is not intended to be used on a low- The ground shields of the digital signal wires must be voltage public network which supplies domestic connected at both ends to a large surface or through premises.
Page 10
Mechanical installation Preparing the mounting fixtures Use the holes and slots prepared for the purpose of fastening the equipment. Vibrations should be avoided. Where necessary, use shock-absorbing lanyards. See figure below. QCIG-10/16 QuerCus SERCOS-II Drive System. Installation Guide. Ref.1801/B...
Page 11
DC BUS connections and power terminal protectors Coup ling The plates that are provided as accessories and designed for the purpose of making DC power bus connections between the QC-APSS-15 and QC-DR-275-SS2 equipment and tighten the M5x16 combined screws. See figures 1A/2A. ...
Page 12
These are INFORMATION. supplied without any terminals. The number of cable Note that FAGOR does not supply the fuses; in other meters is available on request. Lengths of 5, 10, 15, 20, words, the FAGOR QUERCUS system does not include 25, 30, 35, 40, 45 and 50 meters are available for 95, 120 the fuses as accessories.
Page 13
Pow er an d gr ou nd co nn ec tio ns QuerCus SERCOS-II Drive System. Installation Guide. Ref.1801/B QCIG-13/16...
Page 14
Schemas O U T P U T L 1 ' L 2 ' L 3 ' L 1 L 2 L 3 L 1 L 2 L 3 I N P U T 3 x 1 m m QCIG-14/16 QuerCus SERCOS-II Drive System. Installation Guide. Ref.1801/B...
Page 15
Ge ne ra l diag ra m of po wer line connecti on EARLY OPEN EARLY OPEN CONTACT CONTACT - F1 - F2 - F3 IT A MUST TO USE FUSES POWER MAINS - S1 - Q1 MECHANICAL DIFFERENTIAL +24VDC +24VDC MAIN SWITCH BREAKER...