1. Safety & regulations The unit must absolutely NOT be used for ● the discharge of hot air into ducts intended for the flue gas of stoves or 1.1. Safety other combustion appliances. The air Work on the ventilation system may only ●...
Page 3
Safety instructions must be followed in You want to clean the product. ● order to avoid physical injury and/or Want to carry out damage to the product. maintenance on the device. Maintenance and cleaning may only ● The government advises to close be carried out after the appliance windows and doors in case of calamity.
Page 4
1.1.1. Standards and guidelines Warning! The specifications and settings of the appliance comply exclusively with the standards and laws of the country in which the appliance is sold. Applications outside this country can lead to very dangerous situations! The installer must ensure that the entire installation meets the legal requirements, the regulations contained in this document and any other applicable manufacturer's documentation.
2. Product information The BTV-N200 is a fan with a propeller for direct air extraction, 2.1. Versions possibly via a short pipe, suitable for installation in the wall or ceiling. Article Type Description 53-00350 BTV-N200 Bathroom and toilet fan white,...
Page 6
2.3. Product card information Itho Daalderop Description Symbol Unit N200 N201T N202H N203HT N211T Specific energy consumption class - — - — Specific energy consumption, under cold climate conditions kWh/( Specific energy consumption, under moderate kWh/( climate conditions Specific energy consumption, under warm climate conditions kWh/(m2.a)
2.4. Scale drawings 2.5. Scope of delivery Legend Fixing material Documentation 2.6. Unpacking and checking a) Carefully take the equipment out of the box. b) Check the nameplate data and the type for correctness as shown on the sticker on the box. c) Check the equipment for damage and completeness.
Page 8
The product must be taken to a specialised waste The BTV-N200 is the standard version with standard control only. collection centre in the municipality or to a point of sale that With this standard control, the fan starts ventilating at high speed provides this service.
3.2. Installing the fan 6 mm The BTV-N200 series bathroom and toilet fan should be mounted in the wall or the ceiling. c) Drill the necessary holes for the plugs supplied. Use the rear part of the fan itself as a marking template or use the dimensional drawings.
Page 10
i) Mount the cable using the strain relief provided. Connect the wiring as indicated in the chapter "Connecting the power e) Drill a hole for the power cable in the rear of the enclosure, supply". or go to step f if a cable tray is used. Go to step h if no cable tray is used.
5 to 7 mm must be passed through the rubber cable duct and strain relief provided. Mounting the power cable under the strain relief Wiring diagram BTV-N200 Connection of light point Connection diagram for BTV-N201T, N202 H, N203 HT and 211 T...
4. Set up 4.2. Setting the Hygrostat 4.1. Setting the Timer TIMER Switching on by the humidity switch takes place automatically if the humidity level in the room exceeds the set value. The switching point (relative humidity) can be set between 40% (counterclockwise) and 95% (clockwise) by means of the setting The timer (delay time) can be set.
Page 13
6. Faults Warning! The user/consumer must not open the device! The fan does not run any more Cause Solution a) The main switch is in the OFF position. ● Set the main switch to On. b) The fan is not (properly) electric ●...
7. Warranty For all Itho Daalderop products, a standard factory guarantee of two years applies. Within this period, the product or its parts will be repaired or replaced free of charge. Provisions and exclusions are included in our guarantee conditions.
Page 15
Netherlands Declares that the following ventilation units comply with the following directives and standards. BTV-N200, Bathroom and Toilet Fan White BTV-N201T, Bathroom and Toilet Fan White, with Timer BTV-N202 H, bathroom and toilet fan white, with Hygrostat BTV-N203 HT, Bathroom and Toilet Fan White, with Timer and Hygrostat...
Page 16
Netherlands Itho Daalderop Admiraal de Ruyterstraat 2 3115 HB Schiedam E idsupport@ithodaalderop.nl I www.ithodaalderop.nl Only installers: T 010 427 85 65...