Lucent Technologies Lineage 2000 ® Battery Distribution Fuse Bay (BDFB) Table of Contents 1 Introduction General 1 - 1 Documentation 1 - 2 Additional Information 1 - 2 Technical Support 1 - 2 USA, Canada, Puerto Rico, and the US Virgin Islands 1 - 2...
Page 3
Lucent Technologies Lineage 2000 ® Battery Distribution Fuse Bay (BDFB) Monitoring Multiple Alarm Modules for Positive Plants 3 - 27 Reference Data 3 - 27 4 Installation Installation Material Provided 4 - 1 Installation Material Required But Not Provided 4 - 1...
Page 4
Lucent Technologies Lineage 2000 ® Battery Distribution Fuse Bay (BDFB) List of Figures Figure 1-1: J85568C-1 Battery Distribution Fuse Bay (BDFB) 1 - 5 Figure 3-1: 7-foot cabinet (List 1) 3 - 4 Figure 3-2: 7-foot cabinet (List 1, BF)
Page 5
Lucent Technologies Lineage 2000 ® Battery Distribution Fuse Bay (BDFB) Figure 3-19: P101 frame power loss alarm wiring 3 - 33 Figure 3-20: Fuse alarm wiring for positive plant P101 3 - 34 Figure 4-1: BDFB Floor Footprints (Top, 7-foot Cabinet,...
Page 6
Lucent Technologies Lineage 2000 ® Battery Distribution Fuse Bay (BDFB) List of Tables Table 2-A: J85568C-1 BDFB Ordering Information 2 - 1 Table 3-A: Recommended Double Hole Terminal Lugs For Terminating Input Battery And Return Cables (350 KCMIL Maximum) 3 - 15...
Lucent Technologies Lineage 2000 ® Battery Distribution Fuse Bay (BDFB) Introduction General This product manual describes the J85568C-1 Battery Distribution Fuse Bay (BDFB). The J85568C series BDFB is shown in Figure 1-1. It serves as a secondary fuse distribution center for dc power delivered from a central office battery plant to the using equipment.
Lucent Technologies Lineage 2000 ® Battery Distribution Fuse Bay (BDFB) load-bus feeds, output load leads and ground return leads. Suggested cable routing strategies for cable entry are also discussed. Documentation This document (Lucent Technologies 157-005-100) is part of a set of documentation developed to assist engineering and installation personnel.
Lucent Technologies Lineage 2000 ® Battery Distribution Fuse Bay (BDFB) sales representative who will be happy to discuss your specific needs. Europe, Middle If you need product technical support, contact your local Field East, and Africa Support/Regional Technical Assistance Center or contact your sales representative who will be happy to discuss your specific needs.
Lucent Technologies Lineage 2000 ® Battery Distribution Fuse Bay (BDFB) Help Technical Assistance is available at any time through the Lucent Technologies Technical Hotline at 1-800-CAL-RTAC (1-800- 225-7822). For customer service, call 1-800-THE-1PWR (1- 800-843-1797). 1 - 4 Introduction Issue 4 March 1998...
Lucent Technologies Lineage 2000 ® Battery Distribution Fuse Bay (BDFB) L IN J 8 5 E AL FE ED ER BA BD FB FE ED ER BA BD FB FE ED ER BA BD FB FE ED ER BA BD FB...
Ordering Information The following tables are provided to describe the list structure of the J85568C-1 BDFB. Table 2-A provides a summary of the J85568C-1 List structure and Table 2-B a summary of ED- 83127-30 Group options. A detailed description of each of the options on the BDFB is presented in Section 3.
Page 13
Lucent Technologies Lineage 2000 ® Battery Distribution Fuse Bay (BDFB) Table 2-A: J85568C-1 BDFB Ordering Information Description List Optional equipment for a discharge return bus mounted to a fuse panel (maximum of one per fuse panel) Equipment always required in addition to List 20 for terminating battery return cabling to panel position 1.
Page 14
Lucent Technologies Lineage 2000 ® Battery Distribution Fuse Bay (BDFB) Table 2-A: J85568C-1 BDFB Ordering Information Description List Optional material to provide a 2400 ampere discharge return bus arranged for mounting on a 15 or 20 inch ladder type cable rack...
Lucent Technologies Lineage 2000 ® Battery Distribution Fuse Bay (BDFB) Product Description General The Battery Distribution Fuse Bay (BDFB), Model J85568C-1, is available in five cabinet arrangements. These include: Description 7 foot cabinet: 26 inches wide by 15 inches deep...
Lucent Technologies Lineage 2000 ® Battery Distribution Fuse Bay (BDFB) Features The following is a list of the many features provided with this product: • Distributes +/- 24, 48 or 130 volt dc power • 7, 9 or 11-1/2 foot cabinet arrangements •...
Lucent Technologies Lineage 2000 ® Battery Distribution Fuse Bay (BDFB) J85568C-1 Cabinet Cabinet Types Two cabinet types and three cabinet extension options are and Features available with this BDFB: List 1 7 foot Cabinet List 2 9 foot Cabinet List 3 9 foot Cabinet with 2-1/2 foot Extension Cabinet...
Lucent Technologies Lineage 2000 ® Battery Distribution Fuse Bay (BDFB) LINEAGE 2000 BDFB J85568C-1 FRAME ALARM FEEDER BAY: BDFB: Digital Meters Spare Fuse Holders FEEDER BAY: CAUTION FOR CONTINUED PROTECTION AGAINST RISK OR FIRE AND SHOCK REPLACE ONLY THE SAME TYPE...
Lucent Technologies Lineage 2000 ® Battery Distribution Fuse Bay (BDFB) LINEAGE 2000 BDFB J85568C-1 FRAME ALARM FEEDER BAY: BDFB: Removable Digital Meters Riser Cover FEEDER BAY: BDFB: CAUTION FOR CONTINUED PROTECTION AGAINST RISK OR FIRE AND SHOCK REPLACE ONLY THE SAME TYPE...
Lucent Technologies Lineage 2000 ® Battery Distribution Fuse Bay (BDFB) LINEAGE 2000 BDFB J85568C-1 FRAME ALARM FEEDER BAY: BDFB: Spare Fuse Holders FEEDER BAY: BDFB: FEEDER BAY: BDFB: Digital Meters FEEDER BAY: CAUTION FOR CONTINUED PROTECTION AGAINST RISK OR FIRE AND SHOCK...
Lucent Technologies Lineage 2000 ® Battery Distribution Fuse Bay (BDFB) L I N E A G E 2 0 0 0 B D F B J85568C-1 FRAME ALARM FEEDER BAY: BDFB: Removable Riser Cover FEEDER BAY: BDFB: FEEDER BAY: BDFB:...
Lucent Technologies Lineage 2000 ® Battery Distribution Fuse Bay (BDFB) 4-1/2' Frame Frame Mounting Mounting Hardware Hardware Ground Ground Strap Strap 7' Cabinet 7' Cabinet L u c L u c e n t e n t Figure 3-6: 2 foot or 4-1/2 foot extension cabinet Cabinets may be configured for either top or bottom cable entry.
Lucent Technologies Lineage 2000 ® Battery Distribution Fuse Bay (BDFB) NOTICE: Equip fuse panels starting at panel position 1 to eliminate possible cable congestion when installing additional fuse panels in the field Load Bus The bus bars used in the BDFB are sized to provide a 600 ampere Arrangements current carrying capacity for each load bus.
Page 25
Lucent Technologies Lineage 2000 ® Battery Distribution Fuse Bay (BDFB) NOTICE: All bus bars used in this product are copper with a solder plate finish. Bus bars do not require buffing or the application of NO-OX before connection to terminal lugs or other bus bars.
Lucent Technologies Lineage 2000 ® Battery Distribution Fuse Bay (BDFB) List 11 List 13 List 15 Shunt List A List A Figure 3-7: (Left) Busing scheme to fuse panels Figure 3-8: (Right) Connecting multiple battery buses 3 - 12 Product Description...
Lucent Technologies Lineage 2000 ® Battery Distribution Fuse Bay (BDFB) List 23 List 21 List 21 List 20 List 20 List B List 20 List 20 List B List 20 List 20 List 25 Figure 3-9: (Left) Busing scheme to internal discharge...
Page 28
Lucent Technologies Lineage 2000 ® Battery Distribution Fuse Bay (BDFB) Discharge Two optional discharge return bus options are available for Return Bus terminating fuse return leads: (1) Bus bar returns located in the Options BDFB or (2) A return bus located outside the BDFB on a cable rack.
Lucent Technologies Lineage 2000 ® Battery Distribution Fuse Bay (BDFB) cable rack mounting hardware. List K2 provides a bus bar, the connecting bus bar and insulating standoffs for stacking additional tiers as required. List K3 provides the ED83019-50 G1 bus bar assembly, which has a 1200 ampere current rating.
Lucent Technologies Lineage 2000 ® Battery Distribution Fuse Bay (BDFB) List K2 List K1 List K3 Figure 3-11: External discharge return bus options on cable rack 3 - 16 Product Description Issue 4 March 1998...
Lucent Technologies Lineage 2000 ® Battery Distribution Fuse Bay (BDFB) .221 Dia. on .62 Centers (24 Places) Row A for 1st Level Row B for 1st Level .437 Dia. on 1.00 Centers Row D for 2nd Level Row E for 2nd Level (25 Places) 26.00...
Lucent Technologies Lineage 2000 ® Battery Distribution Fuse Bay (BDFB) Table 3-C: Recommended Double Hole Terminal Lugs For Terminating To External Discharge Return Bus Rows B and E (Lists K1 and K2) Rows A and D (List K3) KS-5482 Wire KS-20921 Wire WP-91412 List...
Lucent Technologies Lineage 2000 ® Battery Distribution Fuse Bay (BDFB) Stamping Area for Load Designations LOAD SELECTOR LOAD CURRENT (AMPERES) Digital Meter Display Front View 3 Position Switch Position 1 Position 1 Back View Figure 3-13: Digital meters (front and back views) ED-83127-30 Two types of fuse panels are available.
Page 35
Lucent Technologies Lineage 2000 ® Battery Distribution Fuse Bay (BDFB) Group A provides one 3-70 ampere cartridge type fuse holder, comcode 406686980. This fuse block is UL listed and provides a more compact design than previous fuse holders. The fuse block was developed by USD (Underwriters Switching Devices) to accomodate the WP-92461 series of fuses.
Lucent Technologies Lineage 2000 ® Battery Distribution Fuse Bay (BDFB) When power loss to a panel occurs, a closure exists between pins 1 and 2 and pins 3 and 4 on the output connector (P101), while an open condition exists between pins 1 and 9 and pins 3 and 10.
Page 40
Lucent Technologies Lineage 2000 ® Battery Distribution Fuse Bay (BDFB) Frame Alarm In addition to the individual panel alarm indicators, there is also a frame alarm lamp at the top of the bay. This frame alarm lights when power is lost to a fuse panel or there is a fuse alarm. Power for lighting the frame lamp is brought from the battery plant on an auxiliary battery supply (ABS) lead.
Lucent Technologies Lineage 2000 ® Battery Distribution Fuse Bay (BDFB) single alarm module. All packs will alarm independently by simply disconnecting pin 1. Power Loss Alarm Remote monitoring of power loss is furnished for individual fuse panels. However, power loss alarms will probably not be...
Page 42
Lucent Technologies Lineage 2000 ® Battery Distribution Fuse Bay (BDFB) CR102 Diode bridge, fuse alarm CR103 Voltage blocking diode DS101 Green power LED DS102 Red fuse alarm LED 3 - 28 Product Description Issue 4 March 1998...
Lucent Technologies Lineage 2000 ® Battery Distribution Fuse Bay (BDFB) Monitored PWB Form-C Alarms During Power Loss in BDFB Figure 3-19: P101 frame power loss alarm wiring Issue 4 March 1998 Product Description 3 - 33...
(4) 3/8 inch drop-in anchors with threaded rod Installing When the BDFB is used in an 11-1/2 foot environment, order either the J85568C-1 List 3 or List 1, J. List 3 includes a 9 foot Extension cabinet, a 2-1/2 foot extension cabinet and interconnection Cabinet for 9 hardware.
Lucent Technologies Lineage 2000 ® Battery Distribution Fuse Bay (BDFB) (4) 804220838 screw, HH .625-11x1-1/2 (4) 840058044 lock washer .625 (4) 814251930 washer .625 Interframe ground cable and mounting hardware is also furnished to provide a continuous frame ground to the top of the cabinet.
Lucent Technologies Lineage 2000 ® Battery Distribution Fuse Bay (BDFB) 841068777 Nut, Hex .375-16 841628639 841068174 Bushing, Insulating Stud 3/8 x .52 Inch or .375-16 x 2-1/2 841630163 Bushing, Insulating 841630155 3/8 x .82 Inch Wsh, Flat .375 841630155 Wsh, Hold Down...
Lucent Technologies Lineage 2000 ® Battery Distribution Fuse Bay (BDFB) Discharge return buses located in the BDFB are also equipped with a C.O. ground termination point. Lists 21-26 provide bus bar assemblies for busing battery to each fuse panel. Discharge return cabling from the battery plant is terminated to these assemblies at the top (or bottom) of the cabinet.
Lucent Technologies Lineage 2000 ® Battery Distribution Fuse Bay (BDFB) A stamping area is provided under each switch position for the installer to stamp load bus designations. The recommeded stamping sequence begins with load bus A for panel position 1 and proceeds through load bus F for panel position 6.
Lucent Technologies Lineage 2000 ® Battery Distribution Fuse Bay (BDFB) contain installer stamping areas for load designations, and the size and location of the circuit breaker feeding each load bus. See Figure 4-7. Alarm Outputs Each alarm module provides two form-C contacts for power loss and three form-C contacts for fuse failure.
Lucent Technologies Lineage 2000 ® Battery Distribution Fuse Bay (BDFB) Power Loss Alarm Remote monitoring of power loss is furnished for individual fuse panels. However, power loss alarms will probably not be remotely monitored in most applications because loss of power in a BDFB usually results in a number of other simultaneous alarms from the battery plant and load equipment.
Lucent Technologies Lineage 2000 ® Battery Distribution Fuse Bay (BDFB) to terminal E3. Connect the return lead from the external discharge return bus located on the cable rack to solder terminal E4. For a positive plant (negative ground, reverse these two leads.
Lucent Technologies Lineage 2000 ® Battery Distribution Fuse Bay (BDFB) L u c e n t L IN 2 0 0 Figure 4-6 Accessing Alarm Modules 4 - 14 Installation Issue 4 March 1998...
Lucent Technologies Lineage 2000 ® Battery Distribution Fuse Bay (BDFB) FEEDER BAY: Location ID Breaker/Fuse ID BDFB: Panel Load Voltage Power Fuse Alarm PANEL STATUS Figure 4-7: Load Designation Labels Issue 4 March 1998 Installation 4 - 15...
Lucent Technologies Lineage 2000 ® Battery Distribution Fuse Bay (BDFB) 405095043 DA 15PF179 15 Pos Connector E/W Wire Wrap Pins (Cinch) Figure 4-8: Alarm Output Connector 4 - 16 Installation Issue 4 March 1998...
Page 65
Lucent Technologies Lineage 2000 ® Battery Distribution Fuse Bay (BDFB) Product Warranty A. Seller warrants to Customer only, that: 1. As of the date title to Products passes, Seller will have the right to sell, transfer, and assign such Products and the title conveyed by Seller shall be good;...
Page 66
Lucent Technologies Lineage 2000 ® Battery Distribution Fuse Bay (BDFB) Warranty Period Repaired Product Product Type New Product or Part* Central Office 24 Months 6 Months Power Equipment** The Warranty Period for a repaired Product or part thereof is as listed...
Page 67
Lucent Technologies Lineage 2000 ® Battery Distribution Fuse Bay (BDFB) associated with returning such Product to Seller shall be borne by Customer. Seller shall pay the cost of transportation of the repair or replacing Product to the destination designated by Customer within the Territory.