General Installation Guidelines; List Of Components - UTC SCS-5-08-3 Installation Instructions And Homeowner's Manual

Oil sealed combustion system
Table of Contents

Advertisement

Available languages

Available languages

2.1)
GENERAL
These
instructions
are
technicians who have been trained to install this type
of equipment.
CAUTION
Installation of this equipment by an unqualified person
may lead to equipment damages and/or hazardous
conditions which may lead to bodily harm.
All local and national code requirements as the CSA:
B139-M91
and
the
installation of oil burning equipment, wiring and vent
connections must be followed.
The SCS system should not be installed on
incinerators, condensing type appliances or solid fuel
burning appliances.
The vent terminal unit may be installed through a
combustible or non-combustible wall with a maximum
thickness of 22 inches. The minimum wall thickness is
2 inches.
2.2)
GENERAL INSTALLATION
GUIDELINES
The first step in installing the SCS system is to find
the location that is in accordance with the following
criterias.
A vent should not terminate :
a. Directly above a paved sidewalk or paved
driveway, which is located between two buildings ,
and that serves both buildings;
b. Less than 2.13 meters (7 feet) above any paved
driveway or paved sidewalk;
c. Within 1.8 meters (6 feet) of window, door, or a
mechanical air supply inlet to any building
including soffit opening;
4
INSTALLATION
intended
for
qualified
CSA-C22.1
governing
PART 2
d. Above a gas meter/regular assembly within 1
meter (3 feet) horizontally of the vertical center-
line of the regulator;
e. Within 1.8 meters (6 feet) of any gas service
regulator vent outlet or 1 meter (3 feet) of an oil
tank vent or oil tankfill inlet;
f.
Not less than 0.3 meter (1 foot) above grade level;
g. Within
combustion appliance air intake;
h. Within 1.8 meters (6 feet) of property line;
i.
Underneath a veranda, porch or deck;
j.
So that the flue gases are directed at combustible
material or any openings of surrounding buildings
the
that are within 1.8 meters (6 feet);
k. Less than 1 meter (3 feet) from an inside corner of
an "L" shaped structure;
l.
The bottom of the vent termination opening is less
than 0.3 meter (1 feet) above any surface that
may support snow, ice or debris;
m. So that the flue gases are directed toward
brickwork, siding, or other construction, in such a
manner that may cause damage from heat or
condensation from flue gases.
2.3)

LIST OF COMPONENTS

Please consult figure 2. The parts being shipped with
the SCS system are :
1. A vent terminal assembly with the 8 or 20 feet of 5
inches diameter stainless steel pipe;
2. A electrical box with pressure switch, timer and
relay factory wired and mounted;
3. A 11 feet or 23 feet of 4 inches diameter
aluminum combustion air flexible pipe;
4. A 5 inches diameter Breech plate with test
opening port;
5. A 5 inches diameter collar with gasket;
6. A Burner Flange Adapter with pressure tap;
1.8
meters
(6
feet)
from
another