EDM - 01 SIGNALLING MODULE
DESCRIPTION
The EDM-01 signalling module may
be used in various systems, where
acoustic alarm is needed, e.g. as an
alarm signalling device. The module
is very flexible and applicable in
many circuits owing to the fact that
it is supplied directly from 230 V AC
network.
FEATURES
‫ ی‬Applicable in signalling systems,
‫ ی‬Continuous duty acoustic module,
‫ ی‬Supplied directly from 230 V AC
network,
‫ ی‬High sound level,
‫ ی‬Single-module casing,
‫ ی‬Mounted on TH 35 rail.
The device should be
connected to a single-
phase system accordin-
gly to current standards.
The device connections
CAUTION
will be described in this
manual. Only qualified electricians are
allowed to mount, connect and adjust
the bell. It is necessary to read this ma-
nual before the device mounting. Do not
disassembly the timer casing or you will
lose any warranty rights and expose
yourself to the electric shock hazard.
Before mounting operation make sure
f o
i d
c s
o
n
n
e
t c
n i
g
h t
e
c
o
n
n
e
from the electric network. Use a cross-
head screwdriver of 3.5 mm diameter
to mount the device. The bell should
be carried, stored and used in an ap-
propriate way. Do not mount the bell in
case of any device parts lack, damage
or deformation. In case of malfunction
please notify the manufacturer.
ZAMEL Sp. z o.o.
ul. Zielona 27, 43-200 Pszczyna, Poland
Tel. +48 (32) 210 46 65, Fax +48 (32) 210 80 04
www.zamelcet.com, e-mail: marketing@zamel.pl
TECHNICAL DATA
Connection terminals quantity: 2
APPERANCE
Power terminal (L)
Piezoelectric loudspeaker
t c
o i
n
i w
e r
s
EDM - 01
Power terminals: L, N
Rated voltage: 230 V~
Rated voltage tolerance: -15 ÷ +10 %
Rated frequency: 50 / 60 Hz
Rated current: 15 mA
Load supply indicator: piezoelectric loudspeaker
Connection wire section: 0,2 ÷ 2,50 mm
Operating temperature: -20 ÷ +45
Operating position: optional
Casing fastening: TH 35 rail (according to PN-EN 60715)
Casing IP: IP20 (PN-EN 60529)
Protection class: II
Overvoltage category: II
Pollution level: 2
Dimensions: single-module (17,5 mm) 90x17,5x66 mm
Weight: 51 g
Standard conformity: PN-EN 60669-1; PN-EN 60669-2-1
PN-EN 61000-4-2,3,4,5,6,11
INSTRUCTION MANUAL
2
C
o
Power terminal (N)

Advertisement

loading

Summary of Contents for Zamel EXTA EDM-01

  • Page 1 EDM - 01 SIGNALLING MODULE INSTRUCTION MANUAL ZAMEL Sp. z o.o. ul. Zielona 27, 43-200 Pszczyna, Poland Tel. +48 (32) 210 46 65, Fax +48 (32) 210 80 04 www.zamelcet.com, e-mail: marketing@zamel.pl DESCRIPTION TECHNICAL DATA The EDM-01 signalling module may...
  • Page 2 TOMERS or third parties, to products sold or equipment necessary for the correct operation of products sold; d) defects resulting from force majeure or other aleatory events for which ZAMEL is not liable; e) power supply (batteries) to be equipped with a device in the moment of sale (if they appear);...