Goodman [A/G]PG Service Instructions Manual page 17

Package gas
Table of Contents

Advertisement

PRODUCT DESIGN
If your propane gas appliance is installed in an
excavated area or a confined space, we strongly
recommend that you contact your propane supplier
about installing a gas detecting warning device that
would alert you to a gas leak.
• Propane gas is heavier than air and any leaking gas
can settle in any low areas or confined spaces.
• Propane gas odorant may fade, making the gas
undetectable except with a warning device.
An undetected gas leak will create a danger of
explosion or fire. If you suspect the presence of gas,
follow the instructions on page 6. Failure to do so
could result in serious personal injury or death.
PROPANE TANK SIZING (MINIMUM)
TANK SIZE REQUIRED IF LOWEST OUTDOOR
MAXIMUM GAS
TEMPERATURE (AVG. FOR 24 HOURS) REACHES
NEEDED TO
32°F
20°F
VAPORIZE*
125K BTU/HR
115
115
(50 CFH)
GAL
GAL
250K BTU/HR
250
250
(100 CFH)
GAL
GAL
375K BTU/HR
300
400
(150 CFH)
GAL
GAL
500K BTU/HR
400
500
(200 CFH)
GAL
GAL
750K BTU/HR
750
1000
(300 CFH)
GAL
GAL
* AVERAGE RATE/HOUR WITHDRAWL IN 8 HOUR PERIOD
PROPANE GAS PIPING CHARTS
Sizing Between First and Second Stage Regulator
Maximum Propane Capacities listed are based on 1 PSIG Pressure Drop at 10
PSIG Setting. Capacities in 1,000 BTU/HR
PIPE OR
TUBING
TUBING SIZE, O.D., TYPE L
LENGTH,
FEET
3/8"
1/2"
30
309
700
40
265
599
50
235
531
60
213
481
70
196
446
80
182
412
90
171
386
100
161
365
150
130
293
200
111
251
250
90
222
300
89
201
350
82
185
400
76
172
To convert to Capacities at 15 PSIG Settings -- Multiply by 1.130
To convert to Capacities at 5 PSIG Settings -- Multiply by 0.879
Sizing Between Single or Second Stage Regulator and Appliance*
Maximum Propane Capacities Listed are Based on 1/2" W.C. Pressure Drop at
11" W.C. Setting. Capacities in 1,000 BTU/HR
PIPE OR
TUBING SIZE, O.D., TYPE L
TUBING
LENGTH,
FEET
3/8"
1/2"
5/8"
3/4"
10
49
110
206
348
20
34
76
141
239
30
27
61
114
192
40
23
52
97
164
50
20
46
86
146
60
19
42
78
132
80
16
36
67
113
100
14
32
59
100
125
12
28
52
89
150
11
26
48
80
200
10
22
41
69
250
9
19
36
61
300
8
18
33
55
350
7
16
30
51
400
7
15
28
47
*DATA IN ACCORDANCE WITH NFPA PAMPHLET NO. 54
10°F
0°F
-10°F
-20°F
115
250
250
400
GAL
GAL
GAL
GAL
250
400
500
1000
GAL
GAL
GAL
GAL
500
500
1000
1500
GAL
GAL
GAL
GAL
750
1000
1500
2000
GAL
GAL
GAL
GAL
1500
2000
2500
4000
GAL
GAL
GAL
GAL
NOMINAL PIPE SIZE,
SCHEDULE 40
5/8"
3/4"
7/8"
1/2"
1,303
2,205
3,394
1,843
1,115
1,887
2,904
1,577
988
1,672
2,574
1,398
896
1,515
2,332
1,267
824
1,394
2,146
1,165
767
1,297
1,996
1,084
719
1,217
1,873
1,017
679
1,149
1,769
961
546
923
1,421
772
467
790
1,216
660
414
700
1,078
585
378
634
976
530
345
584
898
488
321
543
836
454
NOMINAL PIPE SIZE,
SCHEDULE 40
7/8"
1/2"
3/4"
1"
1-1/4"
539
291
608
1,146
2,353
368
200
418
788
1,617
296
161
336
632
1,299
253
137
284
541
1,111
224
122
255
480
985
203
110
231
436
892
174
94
198
372
764
154
84
175
330
677
137
74
155
292
600
124
67
141
265
544
106
58
120
227
465
94
51
107
201
412
85
46
97
182
374
78
43
89
167
344
73
40
83
156
320
-30°F
600
GAL
1500
GAL
2500
GAL
3500
GAL
5000
GAL
3/4"
3,854
3,298
2,923
2,649
2,437
2,267
2,127
2,009
1,613
1,381
1,224
1,109
1,020
949
1-1/2"
3,525
2,423
1,946
1,665
1,476
1,337
1,144
1,014
899
815
697
618
560
515
479
17