Installation - Hamilton Beach PrimePour COT2000 Series Operation Manual

Hide thumbs Also See for PrimePour COT2000 Series:
Table of Contents

Advertisement

Operating Instructions
The machine is calibrated to dispense at a ratio
1.
of 3 parts drink mix to one part spirits. If you
are serving a 12-ounce drink, fill the glass with
6 ounces of ice and dispense about 6 ounces
until the glass is full.
2.
The machine holds three bottles
of spirits and a 3-gallon bag of
drink mix. It is recommended the
levels of each be checked before
service each day. The reservoir
holds 0.5 liters of spirits in
addition to the volume in each
bottle. The spirits reservoir is
designed so that the bottle in
the rear of the unit will empty
first and the bottle in the
front will empty last. If the
spirits reservoir runs empty,
air will enter the unit and
cause spitting and coughing
at the tap.
To replace a bottle of spirits,
remove the empty bottle,
remove the cap to the new
bottle, and slide the bottle nozzle over the
bottle. Fold the tip of the bottle nozzle over, and
insert the nozzle into the spirits reservoir, tilting
the bottle upside down. Lower the bottle holder
and secure by tightening the thumbscrew.
The bottle holders need to be centered on the
bottoms of the bottles. Slide the drawer into the
cabinet after the spirits bottles are installed. If
the bottle holders hit the cabinet when sliding
the drawer inside, then adjust the position of
the holders on the bottoms of the bottles.

Installation

Site Preparation
The installation requires a CO
enough such that the cabinet can be pulled out for installation, cleaning, and maintenance. The supply
line pressure must be regulated so that it delivers between 50 and 60 psi. The supply line can be
attached to the unit through a standard 1/4-inch female quick coupler, or the hose can be attached to a
1/4-inch barbed fitting and secured with a hose clamp.
The tap tower and base unit is designed to clamp-mount to a flat table or countertop. The countertop
thickness cannot exceed 3.75 inches. The unit includes 8 feet of hose to run from the faucet to the
base cabinet. The base cabinet needs to be located so that it is within reach of the hose, allowing the
cabinet to be pulled out for installation, cleaning, and maintenance.
3.75"
Maximum
4
supply hose to be within reach of the base cabinet, and it must be long
2
To replace the bag in box (BIB), pull out firmly
3.
on the plunger, and slide the quick connect/
disconnect (QCD) to the side. Discard the empty
BIB.
Install the bag in box
(BIB) by opening the end
of the box and pulling
out the fitting. A cap is
installed over the fitting;
pull to remove. Slide the
fitting into the slot of the
cardboard box. Slide the
box into the unit.
Fully pull out the
plunger on the quick
connect/disconnect
(QCD). Attach the QCD
by sliding it over the
fitting. Firmly push in on
the plunger to engage the
fitting, and slide the BIB
into the cabinet as far as
it will go.
If the BIB runs empty, the
pumps will turn off. When a new BIB is installed,
the pumps will start automatically when the
faucet is opened.
4.
Refer to the Troubleshooting Guide if additional
help is needed.
Follow the steps outlined in Maintenance to
5.
keep your machine in top shape.

Advertisement