EN 60900 or similar standard. Battery may require recycling in accordance with local laws. Contact GNB or regulatory Tray lifting at this area authorities for further information. DO NOT include battery with lead acid battery recycling.
Each person given the task of operating or maintaining the system must have read and understood the instructions. The GNB Lithium-ion battery system may not be operated without precise knowledge of these Installation and Operating Instructions The health and safety information refers to the current directives or without strict adherence to all safety instructions.
Page 4
A rest phase or cooling increase the battery life time and your productivity. is not required for the LiFTFORCE LPX 2.0 Lithium Material Handling Battery. The LiFTFORCE LPX 2.0 Lithium Material Handling Battery system is charged as follows: Bring the vehicle to the GNB certified battery charger.
BATTERY MAINTENANCE Storage Do not open the battery. This can only be done by GNB service Before being placed in storage the battery should be charged to personnel. Only authorized GNB personnel are allowed to open 50 % SOC charged and disconnected from both the vehicle and the battery system.
Charging is forbidden below an internal battery temperature of 32ºF (0ºC.) If the battery internal temperature reaches 122ºF (50ºC) the battery will disconnect. Charge current derating occurs at 113ºF (45ºC.) For cold store operations or operations in a cold environment, please contact GNB. GNB INDUSTRIAL POWER USA/PR 877.462.4636...