COMMISSIONING AND MAINTENANCE
Cleaning inside the storage cylinder
− Loosen the screws (1)
− Remove the flange cover cap (2)
− Remove the insulation (3)
− Unscrew the bolts (4)
− Remove the flange (5) from the boiler using the M8 screw
(6), tightening it as required to create the necessary gap
− Remove the gasket (7)
− Clean inside the storage cylinder and remove any residues
through the access hole.
6
9
Check the seal for wear and replace it if necessary.
− Remove the screw (6) from the flange
On completion of cleaning, follow the above steps in the reverse
order to refit all removed parts.
6
1
2
3
4
9
Screw in and tighten the bolts using a "cross" system in the
sequence 1-2, 3-4, 5-6, 7-8, to exert evenly distributed pres-
5
sure on the gasket. Use the torque wrench with tightening
torque of 10 Nm +2-0.
7
− Fill the storage cylinder's DHW (secondary circuit) and check
that there are no leaks from any of the seals
− Check the performance of the storage cylinder.
− Reposition and manually screw the M8 screw (6)

18 RECYCLING AND DISPOSAL

The device is primarily composed of:
PU (polyurethane)
PE (polyethylene)
ABS (acrylonitrile-butadi-
ene-styrene)
At the end of the device's useful life, these components must be
separated and disposed of according to current regulations in the
country of installation.
9
NOTE: Adequate sorted waste collection, processing and en-
vironmentally-friendly disposal contribute to preventing pos-
sible negative impacts on the environment and health and
promote the reuse and/or recycling of the materials of which
the appliance consists.
9
NOTE: Illegal disposal of the product by the owner shall be
subject to administrative fines provided for by applicable
laws.
17
COMMISSIONING AND MAINTENANCE
2
4
8
Material
steel
water connection washers
7
3
5
1
Component
structural work
insulation
lining and covers

Advertisement

Table of Contents
loading

Table of Contents