We bring better air to life
9. ROUTINE MAINTENANCE
•
Regular maintenance is needed each year. The
•
Before any maintenance work is undertaken:
Stop fan in accordance to regulations and disconnect all poles from mains supply.
o
Wait until impeller is stationary.
o
Make sure that a restart is not possible
o
•
Use only original spare parts tested and approved by the manufacturer.
•
The following safety notes must be observed when maintaining the machine.
•
Replace the ball bearings of the motor whenever the grease utilization period has elapsed in accordance with the maintenance
instructions of the manufacturer.
•
The technical maintenance includes periodic cleaning of the surfaces from accumulated dust and dirt.
•
Use a soft dry brush or a vacuum cleaner to remove dust.
•
Only use usual commercial cleaning material paying attention to the prescribed safety measures and do not use any abrasive
tools (surface protection will be destroyed).
Prior to all servicing work:
•
Bring the fan to a halt in the prescribed manner and completely isolate the fan from the mains supply.
•
Wait until the rotor has come to a halt.
•
Ensure that the machine cannot be switched on again.
•
Clean the fan
General Check:
•
Too much bearing play?
•
Lubricant leaking from the bearings?
•
Surface protective coating damaged?
•
Attention: Conveyed medium too aggressive?
•
Unusual noises during operation?
•
Fan output still sufficient for possibly extended or shortened ducting system?
Clean fan:
•
Unscrews external terminal box for electric installation.
•
Unscrews and remove protection guard and motor impeller.
•
Clean plate casing with inlet cone.
•
Clean motor impeller.
o Do not flood motor.
o Do not bend impeller, blades.
•
Assembly fan.
•
Control whether installation is correct:
Motor impeller must rotate free
o
The gap between impeller and casing must be regular.
o
o Checking direction of rotation is correct.
•
Install the fan into the wall or frame.
•
Push into operation after clean.
•
Connect electric supply of motor.
10. REPAIR
Before any repairs are undertaken please:
•
Stop fan in accordance to regulations and disconnect all poles
from mains supply.
•
Wait until impeller is stationary.
•
Make sure that a restart is not possible.
•
Only use original spare parts manufactured and supplied by
Breeze Fan.
Change of the motor impeller:
Ÿ
Disconnect electric supply.
Ÿ
Remove protection guard.
Ÿ
Unscrew motor suspension and pull out of wall plate
complete with motor impeller.
Ÿ
Remove motor suspension from motor impeller.
Ÿ
Change new motor impeller on protection guard, insert in
wall plate (casing) and secure with screws.
www.breeze.com.vn | breezefans@breeze.com.vn
impeller
blades require thorough cleaning once in 6 months.
Ÿ
Control whether direction of rotation is correct.
Motor and impeller must rotate free.
o
Annular gap between impeller and wall plate must be
o
regular.
Control whether direction of rotation is correct.
o
o Install maintenance cover if have.
Ÿ
Push into operation after repaired.
Ÿ
Connect electric supply of motor.
USER'S MANUAL
Fig 1
Fig 3
Fig 4
Fig 5
AWS SERIES
Fig 2
Fig 6