Thank you for purchasing an Aquatic Life Reverse Osmosis Unit.
When maintained properly, this unit will provide you with years of service.
OVERVIEW
Reverse osmosis is the process of removing
contaminants from tap water using special
semi-permeable membranes. By applying
water pressure across the membranes,
contaminants are concentrated on one side
of the membranes and filtered water on the
other side of the membranes. This is why
reverse osmosis units have a waste water
line as well as a filtered line.
In addition to the membranes, water
is filtered prior to the membrane with
a sediment cartridge to remove larger
particulates, and two carbon blocks to
remove chlorine and other materials.
The cartridges and membrane on your
unit are designed for placement inside the
canisters. It is important the cartridges be
installed in the correct order to effectively
filter the water.
For technical assistance or
warranty issues, contact Aquatic Life at
customersupport@aquaticlife.com
Model# 540474
WARNING:
chlorine, but NOT chloramines.
Test your water and/or check
with your local water company to
find out if you have chloramines
in your water.
WARNING:
carefully before proceeding with
installation. Your failure to follow
any attached instructions and
operating parameters may lead
to the product's failure.
OPERATING GUIDELINES
DO NOT use with water that is micro-
biologically unsafe or of unknown quality
without adequate disinfection before or
after the unit.
The maximum incoming water pressure
for the unit is 80 PSI.
If the pressure is more than 80 PSI, a pressure
regulator is required. If the water pressure is
less than 40 PSI, a booster pump is needed.
Water hardness should not exceed 10
grains per gallon or 170 parts per million.
Operating above this may shorten the
membrane life.
Reverse osmosis filtered water should
not be run through a copper tube.
RO water can leach copper from the pipe,
eventually leading to holes in the pipe.
DO NOT operate the unit unattended.
1
This unit will remove
Please read
See Installation
Video

Advertisement

loading
Need help?

Need help?

Do you have a question about the Classic Hydroponics 200 GPD and is the answer not in the manual?

Questions and answers

Summary of Contents for AquaticLife Classic Hydroponics 200 GPD

  • Page 1 Classic Hydroponics 200 GPD 5-Stage RO Unit Model# 540474 Installation, Operation & Maintenance Guide Thank you for purchasing an Aquatic Life Reverse Osmosis Unit. When maintained properly, this unit will provide you with years of service. WARNING: This unit will remove chlorine, but NOT chloramines.
  • Page 2 Model# 540474 Classic Hydroponics 200 GPD 5-Stage RO Unit Installation, Operation & Maintenance Guide www.aquaticlife.com Contents Contents Float Valve Assembly RO Unit Housing with Mounting Bracket Tubing 1/4" x 20' Collet Tool 1/4" Manual On/Off Valve Flush Valve Assembly (pre-installed)
  • Page 3 Model# 540474 Classic Hydroponics 200 GPD 5-Stage RO Unit Installation, Operation & Maintenance Guide www.aquaticlife.com BECOMING FAMILIAR WITH YOUR RO SYSTEM BECOMING FAMILIAR WITH YOUR RO SYSTEM STAGE 1 - SEDIMENT FILTER USING THE PRESS FITTINGS Recommended change 3-6 months The first stage of your RO unit is a five-micron sediment filter that traps sediment and other particulate matter like dirt, silt and rust which affect the taste and appearance of your water.
  • Page 4 Model# 540474 Classic Hydroponics 200 GPD 5-Stage RO Unit Installation, Operation & Maintenance Guide www.aquaticlife.com BECOMING FAMILIAR WITH YOUR RO SYSTEM BECOMING FAMILIAR WITH YOUR RO SYSTEM RO UNIT HOUSING & Auto Shutoff Solenoid (ASO) Membrane Housing and Elbow Check Valves...
  • Page 5 Model# 540474 Classic Hydroponics 200 GPD 5-Stage RO Unit Installation, Operation & Maintenance Guide www.aquaticlife.com Installation Installed using the manual shut-off valve included with the unit. When you turn off the filtered water, the waste water will also stop. WATER SUPPLY INSTALLATION...
  • Page 6 RO Membrane Model# 540474 Classic Hydroponics 200 GPD Filtered Water 5-Stage RO Unit (connect at Solenoid) RO Membrane Installation, Operation & Maintenance Guide www.aquaticlife.com Adjustable Float Waste Water to Drain PLUMBING If your water pressure is below 40 psi or you wish to increase the efficiency of the unit, This plumbing diagram can be supplied to a booster pump can be added.
  • Page 7 Model# 540474 Classic Hydroponics 200 GPD 5-Stage RO Unit Installation, Operation & Maintenance Guide www.aquaticlife.com PREPARE CARTRIDGES FOR USE INSTALL THE MEMBRANES CARTRIDGE INSTALLATION (cont.) Remove the protective wrap from each cartridge and place the cartridges in the canisters. Make...
  • Page 8 Model# 540474 Classic Hydroponics 200 GPD 5-Stage RO Unit Installation, Operation & Maintenance Guide www.aquaticlife.com REVERSE OSMOSIS UNIT MAINTENANCE OPERATION & CONSIDERATIONS FILTER BASICS Weekly Maintenance The unit includes a pressure gauge to show The membrane does most of the work by the incoming water pressure.
  • Page 9 Classic Hydroponics 200 GPD 5-Stage RO Unit Model# 540474 Installation, Operation & Maintenance Guide LIMITED WARRANTY Lifetime Products LLC warrants that this Reverse Osmosis LIFETIME PRODUCTS IS NOT RESPONSIBLE FOR DIRECT, unit (excluding cartridges and membrane) shall be free SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES...

This manual is also suitable for:

540474