Amana ASXC16 Service And Troubleshooting page 61

Asxc, dsxc, and gsxc condensing units, aszc, dszc, and gszc split system heat pumps with r-410a refrigerant blowers, coils, & accessories
Table of Contents

Advertisement

SERVICING
LED Display
View 6 most recent fault codes and Clear Fault Codes if desired
L6F
(furnace)
Lr n
Restart communications between the indoor and outdoor unit.
Cr
Control Firmware Revision Number
5r
Control Shared Data Revision Number
F5d
Constant Fan Speed as percent of maximum airflow. Default = 30%
EHt
Electric Heater Kit Wattage (kW)
EFd
Electric Heat Off Delay (seconds)
End
Electric Heat On Delay (seconds)
ETF
Electric Heat Airflow Trim (percentage)
Percentage of high stage electric heating airflow to run duirng low
EST
stage electric heat operation
1 = system will try to satisfy the thermostat quickly.
CFS
5 (default) = system will try to satsify the thermostat more slowly.
Select "HI " to enable dehumidification when the thermostat DH
dHL
terminal is energized. Select "Lo" to enable dehumidification when
the thermostat DH terminal is de-energized. (default = HI )
Select number of stages for the non-communicating outdoor unit.
(1AC for single-stage Air Conditioners, 1HP for single stage Heat
O DS
Pumps, 2AC for two stage Air Conditioners or 2HP for two stage heat
pumps)
Indoor Airflow for non-communicating outdoor units. (values based
t on
on 400CFM per ton) (default = 3.0 Ton)
Ct F
Cooling Airflow Trim (default 0%)
CAP
Cooling Airflow Profile setting (default = profile D shown as 4)
Cnd
Cooling Airflow On Delay Time (default = 5 seconds)
CFd
Cooling Airflow Off Delay Time. (default = 60 seconds)
Percentage of high stage cooling airflow to run during low stage
CSt
operation. (default = 70%)
Electric heat operation during defrost. 1 = low stage 2 (default) =
dHS
high stage
Ht F
Heat Pump Indoor Airflow Trim (default = 0%)
HFd
Heat Pump Heating Airflow Off Delay Time (default = 60 seconds)
Hnd
Heat Pump Heating Airflow On Delay Time (default = 5 seconds)
Percentage of high stage heat pump heating airflow to run during
HSt
low stage operation. (defaullt = 70%)
When heat pump heating and electric heat are running at the same
EHA
time, this percentage is used for additional airflow trim
Enables or disables dehumidification feature in the outdoor unit.
dHE
(default = Enabled)
Balance point temperature. The Compressor will not operate below
CbP
temperature. (Default = 0°F)
EbP
Backup Heat Balance Points
Compressor run time between defrost cycles. (default = 30 minutes)
HdI
(2 stage units)
Compressor off delay at the beginning and end of a defrost cycle.
CdL
(default = 30 seconds)
Menu Description
Air Handler Display (B*)
61