Page 1
Any mod- ifications to or abridgments of the document are prohibited without explicit written agreement from J. Schmalz GmbH. J. Schmalz GmbH · Johannes-Schmalz-Str. 1 · 72293 Glatten, Germany · T: +49 7443 2403-0 schmalz@schmalz.de EN-US · 30.30.01.02586 · 00 · 11/20...
6 Checking the Delivery............................. 8 7 Installation............................... 8 Installation Instructions........................ 8 Installing the RECB .......................... 9 7.2.1 Connecting the RECB to the Compressed Air and Electrical Connection......... 9 7.2.2 Optional Compressed Air Connection.................. 13 7.2.3 Mechanical Attachment ...................... 15 8 Maintenance Plan and Cleaning ........................ 16 9 Warranty................................ 16...
ð Failure to follow the instructions in these Assembly instructions may result in injuries! ð Schmalz is not liable for damage or malfunctions that result from failure to heed these instructions. If you still have questions after reading the technical documentation, contact Schmalz Service at: www.schmalz.com/services...
The RECB was developed especially for use on collaborative robot systems. Only specified compact ejectors (SCPSi) from Schmalz may be inserted into the housing of the RECB since the housing has been specially adapted to them.
2.3 Safety The RECB emits noise due to its use of compressed air. WARNING Noise pollution due to the escape of compressed air Hearing damage! 4 Wear ear protectors. 4 The ejector must only be operated with a silencer. WARNING...
2.6 Modifications to the Product Schmalz assumes no liability for consequences of modifications over which it has no control: 1. The product must be operated only in its original condition as delivered. 2. Use only original spare parts from Schmalz.
Note on the specifications for the load limits These specifications apply for static loads. The maximum load limits given here apply to the RECB only. For use in connection with an HRC-capable robot, observe the maximum weight limits determined by the manufacturer of the robot.
1. Compare the entire delivery with the supplied delivery notes to make sure nothing is missing. 2. Damage caused by defective packaging or occurring in transit must be reported immediately to the carrier and J. Schmalz GmbH. 7 Installation 7.1 Installation Instructions...
7.2.1 Connecting the RECB to the Compressed Air and Electrical Connection The RECB must be opened to connect it to the compressed air supply and to establish the electrical connection. ü Allen wrench sizes SW 3 and 6 are available for use.
Page 10
3. To lift the compact ejector, unscrew and remove the M4 screw. 4. Pull the pre-assembled compressed air hose through the housing so that the compact ejector can be easily lifted. This facilitates the installation of the connection cable and compressed air hose. 5.
Page 11
7. Place the compact ejector on the bottom housing shell. Insert the dowel pin (1) into the hole on the compact ejector. ð Ensure that the compact ejector is aligned with the front opening on the housing. This makes it easier to place and position the compact ejector.
Page 12
ð The top housing shell is flush with the lower shell and the connection cable is exposed in the cable bushing. 11. Grip the RECB so that the top and bottom housing shells are held together and then turn the RECB over.
1. Unscrew and remove the three M4x16 mm screws on the bottom (see section 7.2.1, step 1). 2. Rotate the RECB and remove the top housing shell. 3. To lift the compact ejector, unscrew and remove the M4 screw (see section 7.2.1, step 3).
Page 14
10. Check the fit of the hoses in the plug connections (vacuum and compressed air) and ensure complete insertion. 11. Close the RECB (see section 7.2.1, steps 10 to 12). 14 / 18 EN-US · 30.30.01.02586 · 00 · 11/20...
The RECB can be attached to a collaborative robot using a replaceable flange adapter plate. The markings on the flange and on the housing of the RECB must be observed, as these determine the orientation of the display and the suction cup on the robot.
A warranty claim can only be accepted by Schmalz if the product has been installed and used in accordance with its corresponding operating and assembly instructions. In the case of inappropriate handling or use of force, any war- ranty and liability claims shall be void.
The accessories and spare parts listed here are current as of the writing of the Assembly instructions. An up-to-date overview of all accessories and spare parts for the product can be found online at www.schmalz.com 11 Disposing of the Device 1.
12 EC Conformity EU Conformity Declaration EU declaration of incorporation The manufacturer Schmalz confirms that the product described in these operating instructions fulfills the following applicable EU directives: 2006/42/EC Machinery Directive 2011/65/EU RoHs Directive 2014/30/EU Electromagnetic Compatibility The product specified is solely intended for installation indoors in a complete system. Startup is prohibited until the end product has been declared to comply with the Directive 2006/42/EC.