DRINKING FOUNTAIN INSTALLATION
For All Universal KEP( )AC Series Drinking Fountains
A. INSPECTION
Inspect the carton and water cooler for evidence of rough handling and concealed damage. Damage claims should be filed
with carrier.
B. TO PUT WATER COOLER AND FOUNTAIN INTO SERVICE
1. NOTE: Provincial and local plumbing codes may prohibit use of saddle taping valves for water line connection in some applica-
tions. All connections must conform to applicable plumbing codes.
2. Locate and install plumbing and electrical service if required, in accordance with the Rough-in Drawing. Filter units have
additional instructions on a label inside the access panel. Read these before installing unit.
3. FLUSH BUILDING WATER SUPPLY LINE BEFORE INSTALLING UNIT.
4. Install unit on the wall hanger. Wall hanger is shipped fastened to the back of the unit.
5. Install a trap in the waste line and a shut off valve in the water supply line. An in-line strainer is furnished in the "Water Sup-
ply" tube. Connect the "Water Supply" tube to the shut off valve. This connection should not be a solder joint or flare connection
to allow access to the strainer for service. To ease removal of the strainer, a sheet metal screw may be lightly threaded into the
open end. When the unit has an internal waste trap, the trap should be wrapped with the insulating tape to prevent sweating. Use
of the 1 3/4" diameter knockout for a waste line is not recommended because of a potential conflict with ADA* toe space clear-
ance requirements. Check your local building code inspector for approval.
6. Rotate the fan blade by hand to see that it is free of obstructions.
7. Check the available power supply against the water cooler data plate to assure the correct electrical service. This drinking water
cooler is intended to be connected to a 20A minimum ground fault circuit interrupting (GFCI) device to meet UL requirements.
Plug power supply cord into wall outlet. The rear most 1 3/8" diameter knockout in the frame bottom is for an externally located
electrical supply. Make sure the knockout hold edge is smooth and free of any burrs. Use of a Heyco bushing #2184 in the
knocked out hole is recommended in order to prevent damage to the service cord and to close up excess opening around the
cord. Route the cord so it does not interfere with ADA* space requirements.
8. To fill cold water tank on water cooler versions, open water supply line shut-off and push any one of the front or side pushbuttons
to allow water to flow to the bubbler. Run water until stream free of bubbles.
9. To Adjust Bubbler:
a) All Pushbutton models are equipped with a Cartridge Regulator. The KEP8AC and KEPAC have a slot in the shelf below the
Pushbuttons. Insert a screwdriver in the slot to adjust regulator. Turn adjustment clockwise to increase stream height. To ac-
cess the KEPV8AC adjustment, remove the Bezel and Button from the front of the cooler.
C. MAINTENANCE
The only maintenance operation required is the removal of dirt and lint from the condenser where used. Inspection should be made at
3-month intervals. Disconnect the power supply cord, then clean the condenser with a small stiff non-wire or vacuum cleaner attach-
ment brush when required. Observance if this procedure will insure adequate air circulation through the condenser so operation is
efficient and economical.
D. OVERLOAD PROTECTION
The compressor motor, where used, is equipped with an automatic reset protector which will disconnect the motor from the line in
case of an overload.
E. LUBRICATION
This unit is equipped with a hermetically sealed compressor and requires no additional lubrication. The fan motor, where used, on this
unit seldom needs oiling, but if required, a few drops of SAE 10 oil should be used.
02/20 | 036865-001
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KEP AC Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Franke KEP AC Series

  • Page 1 DRINKING FOUNTAIN INSTALLATION For All Universal KEP( )AC Series Drinking Fountains A. INSPECTION Inspect the carton and water cooler for evidence of rough handling and concealed damage. Damage claims should be filed with carrier. B. TO PUT WATER COOLER AND FOUNTAIN INTO SERVICE 1.
  • Page 2 DRINKING FOUNTAIN INSTALLATION For All Universal KEP( )AC Series Drinking Fountains F. TO DISCONTINUE USE OF WATER COOLER 1. Close water shut-off valve. 2. Provide container to catch water to be drained. 3. On the push button model, disconnect the water supply line at the shut off valve and remove the tank drain plug. Actuate and hold in the pushbutton to open the solenoid valve and completely drain the cooler.
  • Page 3: Rough-In Drawing

    ROUGH-IN DRAWING For All Universal KEP( )AC Series Drinking Fountains NOTES: 1. TRAP, STOP VALVE AND ELECTRICAL OUTLET NOT FURNISHED. OPTIONAL - GLASSFILLER 17 5/8 LOCATION 2. ALLOW 4 INCHES [102 MM] MIN. PER SIDE FOR VENTILATION. [448] * 3. RECOMMENDED ADULT BARRIER FREE HEIGHT INSTALLATION SHOWN.
  • Page 4 EXPLODED PARTS BREAKDOWN DRINKING FOUNTAIN To adjust stream height, insert a 1/8" flat blade screwdriver into the slotted hole as shown. The screwdriver will engage the stream height adjuster in the cartridge plunger. Turn clockwise to increase stream height or counter clockwise to reduce stream height. 02/20 | 036865-001...
  • Page 5: Parts Breakdown List

    PARTS BREAKDOWN LIST DRINKING FOUNTAIN Item Single Split Level Single Description...............Chilled ......Chilled ...... Non-chilled Top ................031714-101 ....031714-101 ....031714-101 Bubbler ..............035607-108 ....103607-108 ....035607-108 Washer, under top ............ 028706-030 ....028706-030 ....028706-030 Locknut ..............026824-019 ....026824-019 ....026824--109 Bubbler nut W/ JG (John Guest)........
  • Page 6: Specifications

    WIRING DIAGRAM WIRING DIAGRAM Single KEP(__) series, DRINKING FOUNTAIN Split Level KEP (__) series Single KEP(_) Series Split Level KEP(_)ACSL Series Franke Kindred Canada Limited Franke Commercial Systems 1000 Franke Kindred Road Midland, ON L4R 4K9 1.855.446.5663 Fax 1.866.227.3050 www.franke-commercial.com...
  • Page 7: Entretien

    INSTALLATION DE FONTAINE À BOIRE Pour les fontaines à boire série KEP ( ) AC A. INSPECTION Vérifier que le carton et le refroidisseur d’eau n’ont pas été endommagés par une manipulation brutale. En cas de dommage, les réclamations doivent être adressées au transporteur. B.
  • Page 8: Protection Contre Les Surcharges Thermiques

    INSTALLATION DE FONTAINE À BOIRE Pour les fontaines à boire série KEP ( ) AC D. PROTECTION CONTRE LES SURCHARGES THERMIQUES Le moteur du compresseur est muni d’une protection à réarmement automatique qui coupe l’alimentation électrique du moteur en cas de surcharge.
  • Page 9 DESSIN COTÉ ET DE RACCORDEMENT Pour les fontaines à boire série KEP ( ) AC NOTES : 1. SIPHON, ROBINET D’ARRÊT ET PRISE ÉLECTRIQUE NON FOURNIS. EN OPTION - EMPLACEMENT 17 5/8 DU BEC DE REMPLISSAGE 2. PRÉVOIR 4 POUCES [102 MM] AU MINIMUM DE CHAQUE CÔTÉ [448] DE VERRE POUR LA VENTILATION.
  • Page 10: Vue Éclatée

    VUE ÉCLATÉE FONTAINE À BOIRE Pour régler la hauteur du jet, insérer un tournevis à lame plate de 1/8 po dans le trou avec fente, tel qu'illustré. Le tournevis pénètre dans le dispositif de réglage de la hauteur du jet, situé dans le plongeur de la cartouche. Tourner dans le sens horaire pour augmenter la hauteur du jet ou dans le sens antihoraire pour la réduire.
  • Page 11 LISTE DES PIÈCES DE VUE ÉCLATÉE FONTAINE À BOIRE Numéro d'objet À deux niveaux Description...............Réfrigérée ....Réfrigéré ....Non Réfrigérée Dessus ..............031714-101 ....031714-101 ....031714-101 Robinet de fontaine à boire ........035607-108 ....103607-108 ....035607-108 Rondelle, en dessous ..........028706-030 ....028706-030 ....028706-030 Écrou de blocage .............
  • Page 12: Spécifications

    FONTAINE À BOIRE Single KEP(__) series, Split Level KEP (__) series Série KEP (_) - Une hauteur Série KEP (_) ACSL - Deux hauteurs Franke Kindred Canada Limited Franke Commercial Systems 1000 Franke Kindred Road Midland, ON L4R 4K9 Tél 1.855.446.5663...

This manual is also suitable for:

Kepac seriesKep8ac series

Table of Contents

Save PDF