  • Page 1 Maintenance Guide CCP800 series Emissions Tester CCP800 series Maintenance Guide I324565 Issue B Crypton - A Brand of the Continental Corporation...
  • Page 2 Maintenance Guide CCP800 series Maintenance Guide CCP800 series 1 Vehicle Exhaust Gas Analyser (VEGA) Maintenance Water Trap O2 Sensor Daily Check pipe and probe tip for damage. Do not use any chemical based products to Gently with an airline blow down the clean the water trap.
  • Page 3 Maintenance Guide CCP800 series Maintenance Guide CCP800 series 3 CCP800 series Trolley & Ancillaries Maintenance 4 Vehicle Exhaust Gas Analyser (VEGA) Fault Finding Trolley Power RPM Device (Battery Tach) Leak Test Failure The system is drawing in air, possible causes of a leak test failure are faulty joints, particularly in sample probe/hose assembly and between the two filter bowls.
  • Page 4 Maintenance Guide CCP800 series Maintenance Guide CCP800 series Battery Smoke Meter (DSM) Fault Finding Analyser Battery Charging Smoke head returned to Charging Cradle: To check the charging voltage at the communicating charging cradle: ■ FAST CHARGE (2.5 flashes The DX260-1BT wireless Smoke head contains ■...
  • Page 5 Maintenance Guide CCP800 series Maintenance Guide CCP800 series Removal:- Replacement: ■ Refit the lens housing with the arrow ■ Unscrew the knurled knob (1) and open ■ Your new battery pack is supplied with the pointing upwards (a little silicon grease on up both end caps.
  • Page 6 Maintenance Guide CCP800 series Maintenance Guide CCP800 series 6 Vehicle Exhaust Gas Analyser (VEGA) Consumables cable gland strain relief is tightened ■ Connect the 4-pin multi-plug (4a) and the 2-pin plug (4b) ■ Locate the end plate to the smoke head...
  • Page 7 Maintenance Guide CCP800 series Maintenance Guide CCP800 series 7 Diesel Smoke Meter (DSM) Consumables 8 Product Support 9 Contact Apart from the routine maintenance and Sales adjustments stipulated in this manual the + 4 4 1 2 1 7 2 5 1 4 0 0...
  • Page 8 Continental Automotive Trading UK Ltd, 36 Gravelly Industrial Park, B24 8TA Tel: 0121 725 1366 | Email: support@cryptontechnology.com | Web: www.cryptontechnology.com Crypton - A Brand of the Continental Corporation Legal notice Errors and omissions excepted. The Company reserves the right to introduce improvements in design or specification without prior notice.