Product Information
2.9
Pump test
The pump starts automatically for 10 seconds every 24 hours if the
pump is not in use for prolonged periods. This procedure prevents the
pump from seizing.
2.10
Measurements
1
140
520
=
=
1
9
8
=
=
130
7
Fig. 3
Dimensions [mm]
[1]
Concentric flue adaptor, Ø 100/150 mm coupling end
[2]
Ventilation panel
[3]
Gas connection for wall mounted gas condensing boiler, R 1'' male
thread
[4]
Heating return, G 1½ '' screw fitting with female thread
[5]
Connection set for return, G 1½ '' male thread with flat seal
[6]
Condensate pipe, Ø external diameter 24 mm
[7]
Connection set for gas connection, R 1" female thread
[8]
Connection set for flow, G 1½ '' male thread with flat gasket
[9]
Heating flow, G 1½ '' screw fitting with female thread
6
2
469
156
6
3
4
5
6
40
330
6
0010009975-001
Condens 5000W – 6720813952 (2019/02)