▶ Release the 4 snap fasteners of the burner cover.
The snap fasteners are under tension.
Fig. 54 Opening the snap fasteners
▶ Remove the gas-air unit together with the burner cover.
1.
Fig. 55 Remove the gas-air unit together with the burner cover.
11.3
To clean the burner
▶ Remove the burner gasket and replace if necessary.
Fig. 56 Removing the burner gasket
Condens 5000W – 6720813952 (2019/02)
0010010043-001
2.
0010010044-001
1.
2.
0010010046-001
▶ Take off the burner.
Fig. 57 Removing the burner
▶ Check the burner and gas distributor plate for soiling and cracking.
▶ Clean the burner with compressed air or a soft brush if necessary.
11.4
Cleaning the heat exchanger
NOTICE:
Damage to wall mounted gas condensing boiler.
▶ The heat exchanger has been coated. This coating must not be
damaged.
▶ Steel brushes, abrasives or similar must therefore not be used when
cleaning the various components.
▶ Cover the ignition device.
▶ Clean the heat exchanger.
▶ Rinse the heat exchanger with water if necessary.
▶ In the case of extreme contamination, clean the heat exchanger with
TAB2.
Fig. 58 Cleaning the heat exchanger
11.5
Checking the ignition system
NOTICE:
Damage to the hot surface igniter.
The glow ignitor unit is made of breakable material.
▶ Handle with care.
Inspection and service
1.
2.
0010010048-001
0010010050-001
27