Terminal Connections

External sensors use standard thermostat wiring;
and may be wired using two wires of a multiple wire
cable. Wire run should not exceed 300 feet (100m).
Terminals CM- and CM+ will require wiring as
specified in "Table 3. Twisted Pair Communication
Wiring (SysBus - Yellow)" on page 4.
Table 4. Twisted Pair Communication Wiring
(SysBus - Yellow)
Terminals

Purpose

10VDC to damper actuator
DO
Common to damper actuator
SG
Heat relay
HR
Fan relay
FR
Relay hot
RH
24VAC
R
External indoor temperature sensor
T
T
(10KΏ or 11KΏ)
OC
Occupancy sensor
OC
Zone bus communications (L
CM-
CM+
Connection)
24VAC common
C
IMPORTANT!
Damage to the ComfortSense 8500 may occur if
24VAC polarity is not maintained.
Wiring CS8500 (with or without CO
Below are the terminal designations and a general
description of their purpose.
1.
Connect
wiring
applicable controller.
2.
Connect external sensors if applicable.
3.
Seal the hole in the wall with a suitable material
to prevent drafts from entering the CS8500
case.
4.
Configure CS8500 and equipment for system
type and test system.
6
)
2
between
CS8500
and