10. Electrical characteristics

Model name
Voltage
Power
supply
Frequency
Max operating current *1
Starting current
Circuit breaker current
Power cable
Wiring
spec. *2
Connection
cable *3
*1: Maximum operating current is the total current of the indoor unit and the outdoor unit.
*2: Selected sample based on Japan Electrotechnical Standards and Codes Committee E0005. As
the regulations of wire size and circuit breaker differ in each country or region, select appropriate de-
vices complied to the regional standard.
*3: Limit voltage drop to less than 2%. If voltage drop is 2% or more, increase cable conductor size.
mm
Cross-sectional area
mm
Limited wiring length
AOYG09KVCA
AOYG12KVCA
V
Hz
A
8.5
A
4.1
A
10
2
2
m
- 53 -
AOYG14KVCA
230
50
8.5
12
5.7
6.2
10
16
1.5
1.5
21