Connector Camera - BENQ-SIEMENS Vodafone C72 Service Manual

Table of Contents

Advertisement

21 Connector Camera

Fault Symptoms
Customer:
No or bad Camera
Exchange
Connector
Connector Camera
Use hot air blower to remove defective component. Avoid excessive heat! Watch surrounding components!
Resolder new component afterwards.
E-commerce order number:
Soldering temperature:
IRIS Diagnose Code:
Technical Documentation
TD_Repair_L1-L3_C72_R1.0.pdf
Camera connector
Problems
Watch for oxidation and
damaged pads of the
Connector
not
okay
Check the status of the
Connector visually
not
okay
Use the resistor test
function of a
multimeter to check
connection between
spring contacts and
soldering contacts.
The value must be
~0Ω
L36197-F5008-F341
240 - 255°C
9B100 Functionality / Integrated Camera / No Function
Company Confidential
GRT:
Camera Problems
okay
okay
2005©BenQ
Release 1.0
Back to customer
without repair
caused by customer
SCRAP
- has to be send
separately to WSC
- check for twisted or
bent contacts
- check for dry joints
Continue with
higher repair level
Page 42 of 45