Battery Interface Circuit

Figure 50
illustrates the battery interface circuit. The BSI voltage level for different
power-up modes:
• normal mode - 1.23V
• test mode - 170mV
• local mode - 90mV
The UEMEK has the following programmable charge cut-off limits:
• VBATLim1=3.6 V (Default)
• VBATLim2L=5.0 V
• VBATLim2H=5.25 V
When the voltage rises above VBATLim1, 2L, 2H+ charging stops. No change is done in
operational mode. When the voltage decreases below VBATLim-, charging restarts.
The duty cycle range is 0% to 100%. The maximum charging current is limited to 1.2 A.