THEORY OF OPERATION

Pentair® Everpure® Oxidice is a disinfection system that treats
the ice machine's water supply using dissolved ozone. It supports
the reduction of the growth of bacteria, molds, yeast, and other
contaminants by disinfecting the air, water and surfaces within the
machine.
Using only 45 watts of electricity, Oxidice takes oxygen from the air
and converts it into ozone (O
ated by sunlight, and then bubbles that ozone into the water sump
inside the ice machine.
Since ozone is created using only oxygen and electricity, any
unused ozone quickly breaks down to oxygen, discharging no harsh
chemicals into the water. As a result, the taste of the water and
subsequent ice produced is not impacted.
This system will adapt to any sized ice machine via a simple ozone
delivery line into the water reservoir. The system delivers ozone
through a single hole in the ice machine to a diffuser in the sump.
As the ozone passes through the diffuser it transforms into small
bubbles. The small bubbles allow some of the ozone to become
dissolved in the water, providing a sanitizer in the water.
Any ozone that does not dissolve will mix with the air inside the ice
machine, thus sanitizing all of the remaining internal
surfaces.

INSTRUCTIONS

1. Save these instructions. Before using, please read the owner's
manual carefully.
2. Disconnect power before servicing.
3. Make sure Pentair® Everpure® Oxidice system is mounted
horizontally (see installation instructions). Do not mount to a
wall vertically or at any angle. The system may also be placed on
a flat, horizontal surface.
4. Do not operate the system with the cover removed.
5. Do not use an extension cord.
6. Oxidice should be cleaned with a damp cloth. Avoid using harsh
chemicals, abrasives, or cleaners.
The system has only been evaluated for mechanical,
WARNING:
electric shock, and fire hazards. The method to control
ozone release or the effectiveness of the water
treatment has not been investigated.
7. This system is not intended for use by persons with reduced
physical, sensory or mental capabilities, or lack of experience
and knowledge.
8. If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent, or similarly qualified persons in
order to avoid a hazard.
), a very powerful natural oxidizer cre-
3
SPECIFICATIONS
• System (Model/Part No.)
CD385
• Ozone Output
150 mg/hr @ 2.0 SCFH on ambient air
• Outlet
3/16" barb
• Ambient Requirements
32° - 90°F; (0° - 32°C) 10 - 75% RH non-condensing
• Dimensions
5.59" H x 10.0" W x 3.83" D
(14.2 cm x 25.4 cm x 8.6 cm)
• Air Flow
0.5-2.0 SCFH, back pressure 2 PSI max
• Power
90-265VAC/50-60Hz
• Power Consumption
6' (1.8m) 3-prong cord
• Mounting
Z-bar
• Weight
3.5 lbs (1.59 kg)
FEATURES
• Variable ozone output to fit any sized ice machine
• LED status indicators
• Fast and simple installation
• Microprocessor controlled
• Treats both the water and surfaces in the ice machine
• Unique application method
• Automated service timer
• No chemicals - nothing to fill or recharge
• Only byproduct is oxygen*
*Any ozone that does not react with another compound will break down to oxygen. In water, half of
the unused ozone will revert back to oxygen in 20 minutes at 680F. In air, half of the unused ozone
will revert back to oxygen in 3 days at 680F.