Preparation And Filling; Priming The Pump; Exiting Priming Mode - Canadian Spa BP Series Owner's Manual

Patio spa
Table of Contents

Advertisement

O K A N A G A N / S A S K A T O O N / G A N D E R / M U S K O K A S P A S
Fill it up!

Preparation and Filling

Fill the spa to its correct operating level. Be sure to open all valves and jets in the plumbing system before filling to allow
as much air as possible to escape from the plumbing and the control system during the filling process.
After turning the power on at the main power panel, the top-side panel display will go through specific sequences. These
sequences are normal and display a variety of information regarding the configuration of the hot tub control.
Priming Mode - MO19*
This mode will last for 4-5 minutes or you can manually exit the priming mode after the pump(s) have primed.
Regardless of whether the priming mode ends automatically or you manually exit the priming mode, the system will
automatically starts normal heating and filtering at the end of the priming mode. During the priming mode, the heater is
disabled to allow the priming process to be completed without the possibility of energizing the heater under low-flow or
no-flow conditions. Nothing comes on automatically, but the pump can be energized by pushing the "Jets"
or "Aux" buttons.

Priming the Pump

As soon as the above display appears on the panel, push the "Jets" button once to start the Pump in low-speed and then again
to switch to high-speed. will now be running in high-speed to facilitate priming. If the pump has not primed after 2 minutes, and
water is not flowing from the jets in the spa, do not allow the pump to continue to run. Turn off the pump and repeat the process.
Note: Turning the power off and back on again will initiate a new pump priming session. Sometimes momentarily turning the
pump off and on will help it to prime. Do not do this more than 5 times. If the pump will not prime, shut off the power to the spa
and call for service.
Important: A pump should not be allowed to run without priming for more than 2 minutes. Under NO circumstances should
a pump be allowed to run without priming beyond the end of the 4-5 minute priming mode. Doing so may cause damage to
the pump and cause the system to energize the heater and go into an overheat condition.

Exiting Priming Mode

You can manually exit Priming Mode by pressing the "Warm" or "Cool" button. Note that if you do not manually exit the
priming mode as described above, the priming mode will be automatically terminated after 4-5 minutes. Be sure that the
pump have been primed by this time. Once the system has exited Priming Mode, the top-side panel will momentarily display the
set temperature but the display will not show the water temperature yet, as shown below.
This is because the system
requires approximately 1 minute
of water flowing through the
heater to determine the water
temperature and display it.
(10)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

OkanaganSaskatoonGanderMuskoka

Table of Contents