Installation, Relocation And Inspection; Specifications - Mitsubishi Electric MS-30RV Operating Instructions Manual

Table of Contents

Advertisement

INSTALLATION, RELOCATION AND
INSPECTION
Installation place
Avoid installing the air conditioner in the following
places.
I Where flammable gas could leak.
CAUTION
Do not install the unit where flammable gas could
leak.
If gas leak and collect around the unit, it may cause an
explosion.
I Where there is much machine oil.
I Salty places such as the seaside.
I Where sulfide gas is generated such as a hot spring.
I Where oil is splashed or where the area is filled with
oily smoke.
Electrical work
I Provide an exclusive circuit for the power supply of
the air conditioner.
I Be sure to observe the breaker capacity.
WARNING
The customer should not install this unit.
If installation is done incorrectly, it may cause a fire,
an electric shock, or injury from the unit falling, water
leaking, etc.
CAUTION
I Earth the unit.
Do not connect the earth to a gas pipe, water pipe,
lightning rod or the earth of a telephone. If the
earthing is incorrect, it may cause an electric
shock.
I Install an earth leakage breaker depending on the
place where the air conditioner is to be installed
(humid places, etc.).
If the earth leakage breaker is not installed, it may
cause an electric shock.
If you have any questions, consult your dealer.
16
Keep the outdoor unit 3 m or
more away from the antennas
of TV sets or radios.
Inverter-type
To prevent the effects
fluorescent lamp
of a fiuorescent lamp,
keep as far apart as
possible.
Well-
ventilated
Keep a space
dry place
to prevent the
picture
distortion or
100 mm or
the noise.
more
500 mm or
1 m
TV
more
or more
3 m
or more
Radio
Inspection and maintenance
I When the air conditioner is used for several seasons,
the capacity may be lowered due to dirt inside the
unit.
I Depending on the condition, an odor may be gener-
ated or dehumidified water may not drain out
smoothly due to dirt, dust, etc.
I It is recommended that the unit be inspected and
maintained (charged) by specialist in addition to nor-
mal maintenance. Consult your dealer.
Operating sound considerations
I Do not put an object around the air outlet of the out-
door unit. This may lower the capacity or increase
the volume of the operating sound.
I If an abnormal sound is heard during operation, con-
sult your dealer.
Relocation
I When the air conditioner is to be removed or re-in-
stalled because of rebuilding, moving, etc., special
techniques and work are required.
WARNING
Repairs or relocation should not be done by the cus-
tomer.
If this is done incorrectly, it may cause a fire, an
electric shock, or an injury from the unit falling, wa-
ter leaking, etc. Consult your dealer.
Disposal
To dispose of this product, consult your dealer.

SPECIFICATIONS

Model
Function
Power supply
Capacity
kW
Input
kW
Indoor
kg
Weight
Outdoor
kg
wall, etc.
Refrigerant filling
kg
capacity (R-22)
Indoor
IP code
Outdoor
Permissible
LP ps
MPa
excessive
operating
HP ps
MPa
pressure
Noise level
Indoor
dB(A)
(Hi)
Outdoor
dB(A)
Note:
1. Rating condition
°
Cooling — Indoor:
27
C DB, 19
°
Outdoor: 35
C DB
MS-30RV
Cooling
~ /N, 220-240V, 50Hz
8.4
3.38-3.52
16
78
2.40
IP20
IP24
1.3
4.2
47
55
2. Guaranteed operating range
°
C WB
Indoor
32°C DB
Upper limit
23°C WB
Cooling
21°C DB
Lower limit
15°C WB
Outdoor
43°C DB
21°C DB

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents