using the frame in a furniture unit
When installing the frame into a WC furniture unit, some struts may need to be removed. Always check before cutting that
the unit integrity will not be compromised. Units can be screwed to adjoining units in a run where possible to add further
strength.
Front struts in a WC furniture unit will cause the frame to be spaced away from the main WC facing fascia of a WC unit.
This will create a void which will need to be filled (between the frame and the back of the main fascia) to stop the main
fascia bowing in when the WC is in use.
You may need to remove the feet in a fitted furniture WC Unit to facilitate room for the frame. The unit can be wall hung
instead.
Any back rails in a WC Unit must be removed or repositioned to the back of the unit if they are not already. Frame brackets
must screw directly into a solid wall. Screwing into a rail or strut that is not secured up against a solid wall will not prove
strong enough when the frame is in use.
general care & safety
Wall plugs supplied are ONLY suitable for solid stone/brick walls. They are not suitable for use in aerated blocks or similar.
If fixing to a stud wall, sufficient extra internal reinforcements must be made to the wall. Screws must locate into suitably
reinforced studs and noggins.
Take care using power tools – The use of a residual current device (RCD) is recommended. Beware of hidden cables or
pipes when drilling.
This product can be dangerous if installed incorrectly. This product must be installed by a qualified plumber or installer. It
is the installer's responsibility to check that the fixings are suitable for the installation in hand.
Cistern fittings are suitable for Water pressure: 0.2 - 10 bar. Do not add caustic chemical substances (eg containing
chlorine compounds or similar) into the cistern. These can damage the valve components and cause failure.
Before starting to enclose the frame, the system must be first tested for leaks before 2nd fix commences. Using the help
of a second person to hold the pan in place on the frame, turn on the water supply and flush the pan to check for leaks.
820mm wall hung frame
fitting instructions
Please read completely first before commencing.
Please retain for future reference.
This product must be installed by a qualified fitter or plumber in accordance with and meet the requirements of
exploded diagram
Square flanged
elbow fitting F 1/2"
15
EN 14055:2010 &
EN 14124: 2004
V4.PL.13.08.18015
Load Tested to EN 997: 400KG
the Water Supply (Water Fittings) Regulations 1999 and Scottish Byelaws 2004
Protective case
Cistern plate
Flexible pipe
Stop valve
Air hose pipe
Inlet pipe
Waste pipe kit
110mm waste adaptor
Adjustable foot x2
TR9005
Inlet pipe bung
Waste pipe bung
Flexible
sheath(x2)
Fill valve
Flush valve
Wall Bracket x4
Fixing Bolts, Washers and Plugs x 4
Frame
8x M8 x 25mm
Bolts & Washers
(Secure brackets /
plates to frame)
Flat Plate x2
Pan Connector kit
Floor fixing screws x 2
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the TR9005 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Roper Rhodes TR9005

  • Page 1 Please read completely first before commencing. Please retain for future reference. TR9005 Front struts in a WC furniture unit will cause the frame to be spaced away from the main WC facing fascia of a WC unit. This will create a void which will need to be filled (between the frame and the back of the main fascia) to stop the main fascia bowing in when the WC is in use.
  • Page 2 adjustments & maintenance Flush plate cut out 170-215 The water level in the cistern can be adjusted by turning the adjustment controls with a screwdriver - clockwise will increase the water level, anti-clockwise will lower the water level. 95/115 Ø110/Ø90 170 min (Wall Hung Frame dimensions - Top mounted flush plate shown) installation of waste pipe...
  • Page 3 installation of flush plate installation of wall hung frame Take care using power tools – The use of a residual current device (RCD) is recommended. Beware of hidden cables or pipes when drilling. Assemble the brackets to the frame as shown, using 8x 25mm hex head bolts &...
  • Page 4 installation of isolation valve installation of wall hung pan Once the partition or furniture is assembled and complete, the pan can be fitted. PTFE Inlet Pipe The isolation valve should come pre-assembled with the cistern. If the valve needs replacing, the above instructions show the correct installation procedure.
  • Page 5 Check out our full range of Bathroom Suites Bathroom Suites By Range Cloakroom Suites Toilets Bathroom Sinks / Wash Basins Bidets Baths Wide variety of toilets Close Coupled Toilets Wall Hung Toilets Back To Wall Toilets Furniture unit toilets Huge Selection of Baths Acrylic Baths Steel Baths Shower baths...