8.5 TELEPHONE LINE TESTS

TOP PREVIOUS NEXT
1. Switch on the 9V power supply.
2. Connect a telephone cord from the base unit to the line/DTMF test set.
3. Enter "HOOKOFF" from the PC to invoke an off-hook condition.
4. Set the current limit to 40mA on the line simulator.
5. Enter "HOOKON" from the PC to invoke the on-hook condition.
6. Check that the line current has dropped to 0 ± 0.5mA.
7. Enter "HOOKOFF".
8. Use a DMM to test the off-hook voltage at TP50. It must be 6.5V ± 1.0V.
9. Enter "LINEIMP 1" at the PC to switch on the pulse-dialing impedance.
10. Check the DC voltage at TP50. It must be < 3.5V.
11. Enter "LINEIMP 0" at the PC to switch off the pulse-dialing impedance.
12. Enter "DTMF_UP" to make the base generate the upper DTMF frequency.
13. Check that the upper frequency is detected by the line/DTMF test set. Must be 1477Hz ± 1.5%.
14. Enter "DTMF_LO" to make the base generate the lower DTMF frequency.
15. Check that the lower frequency is detected by the line/DTMF test set. Must be 852Hz ± 1.5%.
16. Switch off the 9V power supply.
17. Disconnect the telephone line and reconnect the base to the Bell oscillator.
18. Switch on the 9V supply.