EDS SCL-01 Technical Information

Explosion-proof atex spark detector

Advertisement

Quick Links

EDS - TECHNICAL INFORMATION
Explosion-proof
ATEX Spark Detector
SCL-01
TECHNICAL MANUAL
EDS srl - V. Ca' Nova Zampieri 6 - 37057 S. G. Lupatoto - VERONA - Tel. +39045547529 - Fax +390458750065
Email: eds@eds.eu - Web: www.eds.eu
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SCL-01 and is the answer not in the manual?

Questions and answers

Summary of Contents for EDS SCL-01

  • Page 1 EDS - TECHNICAL INFORMATION Explosion-proof ATEX Spark Detector SCL-01 TECHNICAL MANUAL EDS srl - V. Ca' Nova Zampieri 6 - 37057 S. G. Lupatoto - VERONA - Tel. +39045547529 - Fax +390458750065 Email: eds@eds.eu - Web: www.eds.eu...
  • Page 2 EDS - TECHNICAL INFORMATION SPARK DETECTOR SCL-01 The SCL-01 is a spark detector suitable for the detection of very fast sparks that can be transported by pipelines of silos or warehouses for the storage of flammable materials such as sawdust, cotton yarn, cereal powders, metal powders, etc.
  • Page 3: Operation Verification

    SCL-01 enters in alarm condition, and its output relay is energized 1.12...
  • Page 4: Maintenance

    EDS - TECHNICAL INFORMATION the relay output of EV521 (if present) For other applications, you need a measurement. T4 - response time of VL electrovalve Therefore, knowing the 3 fundamental parameters of T5 - time of water filling of the part of the pipe the formula, the calculation is very simple.
  • Page 5: Technical Data

    EDS - TECHNICAL INFORMATION Follow scrupulously the rules relating to the - Periodically check the operation and thightness connections and the use of electrical equipment in of the electrovalves. A defect in the seal can result in areas with potentially explosive atmospheres.
  • Page 6 EDS - TECHNICAL INFORMATION distance distanza System response tempo di risposta del sistema 0,25s time 0.25 sec Suggested area zona consigliata do not use non usare velocità fluid speed del fluido [m/s] fig.1 fig.1...
  • Page 7 EDS - TECHNICAL INFORMATION Components side view external view ALARM LED LED ALLARM E SENSITIVITY SENSIBILITA' TIM E ATTRACTION TEM PO ATTRAZIONE Fig. 2 Attraction time for relay output. Selection is done inserting the corresponding jumper (one only) JP3 - 1 sec...
  • Page 8 EDS - TECHNICAL INFORMATION Fig. 3 -Example of a system with one SCL-01 Pipe Water feed pipe SCL01 Spark Detector Spraying Nozzle Fig. 4 - Example of system with 2 SCL-01 electrovalve electrovalve pressure gauge pressure gauge water supply pipe...
  • Page 9 EDS - TECHNICAL INFORMATION SCL-01 SPARK DETECTOR MECHANIC MOUNTING SCL-01 detector rivelatore SCL-01 washer rondella threaded rod M8 barra filettata M8 nut M8 DS1207 dado M8 fig.6 seal washer guarnizione rondella pipe tubazione 80.0 Ø130.0 TEMPLATE 160.0 fig.7...
  • Page 10 The information contained in this document have been carefully checked and are reliable. By the way EDS company is not responsable in any way for possible inaccurancies or errors and it reserves the right to perform changes in any part of this document and/or product, to improve the quality, reliability or the design.
  • Page 11: Technical Information

    • food industry: cereals The EDS SCL01 Spark Detector is an electronic device suited to If the pipes have a large diameter (over 0,5 m.) several SCL01 detect spark in pipes and channels that transport varoius types of detectors can be used to obtain a better security level combustible materials headed to a storing silo.
  • Page 12 1-10 sec • weight: 2 Kg • terminals to connect a remote working test button Installation example with SCL-01 water feed pipe water cone electrovalve transporting pipe pressure meter SCL-01 nozzle Installation example with two SCL-01 shutter SILO...
  • Page 13: Tecnical Information

    EDS - TECHNICAL INFORMATION Accessories for Spark Detection Systems TECNICAL INFORMATION VL-34-24 - electrovalve - Max pressure: 20 bar - NC normally closed pilot operated - Flow rate: 5 m3 / h (83litri/minuto) - Interception of liquid - Electromagnet: 10 VA...

Table of Contents