Infrared Does Not Work; Fig 13 Fault Tree, Infra Red - Nokia NPM-2NX Troubleshooting Manual

Hide thumbs Also See for NPM-2NX:
Table of Contents

Advertisement

CCS Technical Documentation

Infrared does not work

Infra Red not working
Measure Vflash1 from IR
module VCC(pin6), should
be 2.78V
Check R350, R351, C351
and V350
ST_IR_LOOP_TEST(in
BB Self Tests) in Phoenix
FAIL
Measure Tx Data from
IR module(pin3)
2.78V, 9.6/115.2kbps
UPP or UEM is faulty
Issue 1 07/02
Fault tree, infra red
Figure 13:
FAIL
OK
FAIL
OK
Use
OK
Measure Rx Data from
OK
IR module(pin4)
OK
Change UEM
ãNokia Corporation
Change
UEM(D200)
Replace faulty
component(s)
Use
ST_IR_IF_TEST(in
BB Self Tests) in
Phoenix
FAIL
OK
FAIL
Change IR module
NPM-2NX
Troubleshooting
Phone OK
Page 25