The Shot Function - Schippmann CS-8 Series Owner's Manual

Dual quadrature low frequency oscillator
Hide thumbs Also See for CS-8 Series:
Table of Contents

Advertisement

Triangle
output
+4 V
State
value
0 V
-4 V
+5 V
Run/Set input
0 V
Note: The overline above the word "Set" of "Run/Set" indicates a low active
logic level (0 V).

8.6 The Shot function

The display (10) is normally off. The shot function becomes active as soon as
the Num controller (7) is moved away from full CCW position ("0"). The
oscillator stops immediately an goes to the pre-selected state value. By
passing through the numbers 1 - 16 of the dial the display displays that
numbers, whereas the decimal point lights up beginning with the number "10"
and the display continues with 0 - 6, thus from 10 - 16. The selected number
corresponds to the number of oscillations (Counts) after starting the shot
(Run) via a 0 V -> +5 V transition at the Run/Set jack (15). Once started the
shot, even when the transition returns to 0 V, the shot will be completed.
However, another 0 V -> +5 V transition during a shot execution will restart the
shot again, i.e. a reset to the selected count number and state value and
continuing the oscillation without any break. During a shot the display (10)
counts backwards to zero and displays after the completed last oscillation the
selected number.
This number (Counts) can be changed during the shot execution without any
effect on this shot. But after the completed shot the new number will be
displayed and becomes active for the next shot. If the Num controller (7) is at
CS-8 Series DLFO Rev1.3, March 2021
downward
direction
(left side scale)
Fig. 6b State - Run/Set
-19-
upward
direction
(right side scale)
time
time