Further from the mid position (2) to full CW the state value arises again to
more positive voltages (from -4 V to +4 V), whereas the direction is now
upwards.
Hint: In a strong asymmetrically setting of the slope value (controller 9), close
to full CCW or CW there will be a sound difference with synchronization when
the LFO operates at audio frequencies.
8.5 Synchronization, Run/Set
A positive transition beyond a trigger level of about +3 V at the sync jack (11)
leads to a synchronizing jump to the current state value, whereas the LFO
continues oscillating. The Run/Set jack (15) is internally tied via a switching
contact to +5 V, that the LFO can free oscillate in normal mode. A plugged
cable even open ended or with applied 0 V causes a permanent set of the
triangle to the state value until the applied voltage becomes +5 V (or unplug
the cable) to release the oscillator. Fig. 6a, 6b visualize the effect of Sync and
Run/Set in free running mode.
Triangle
output
+4 V
State value
0 V
-4 V
+5 V
Sync input
0 V
CS-8 Series DLFO Rev1.3, March 2021
downward
direction
(left side scale)
transition
Fig. 6a State - Sync
-18-
upward
direction
(right side scale)
time
time