The State Parameter - Schippmann CS-8 Series Owner's Manual

Dual quadrature low frequency oscillator
Hide thumbs Also See for CS-8 Series:
Table of Contents

Advertisement

CS-8 Series DLFO Rev1.3, March 2021
Sine
Triangle
(reference)
Co-Tri
Cosine
Pulse
Fig 5b. The slope effect (controller 9 (27) on right side)
The algebraic sign of the rectangle is positive (+5 V) during the rising phase of
the triangle or respectively at positive values of the Co-triangle and negative (-
5 V) during the falling phase of the triangle or respectively at negative values
of the Co-triangle.

8.4 The state parameter

The state value becomes relevant for the synchronization and for setting the
LFO to a certain voltage value. The CV-jack (1) and the controller (2)
determines the state value. Thereto the imagery at the dial of controller (2) is
to understand as follows. The little dot on the triangle edge marks the voltage
value (state) to which the triangle output will be set in case of a sync input
trigger at jack (11) or with a set signal (0 V) at jack (15). The arrow implies the
direction (rising/falling) of the triangle after the sync/set event. If the
controller (2) is in mid position, a voltage range of ±5 V at jack (1) is equal to
the full range of controller (2). The values of controller (2) and jack (1) sum up.
On the left side of the dial (2), from full CCW to mid position, the full range of
the triangle output voltage (from +4 V to -4 V) will be passed through, whereas
the triangle direction is always downwards to more negative voltage values.
-17-