Troubleshooting - WilTec 61974 Operation Manual

Hydraulic car jack
Hide thumbs Also See for 61974:
Table of Contents

Advertisement

Troubleshooting

Problem
Possible Causes
Jack will not lift
load
Jack bleeds off
after lift
Jack will not lower
after unloading
Poor lift perform-
ance
Will not lift to full
extension
© by WilTec Wildanger Technik GmbH
http://www.WilTec.de
http://www.aoyue.eu
http://www.teichtip.de
Release valve not closed
tightly
Overload condition
Air supply inadequate
Release valve not closed
tightly
Overload condition
Hydraulic unit malfunction
Reservoir overfilled
Linkages binding
Fluid level low
Air trapped in system
Fluid level low
Item 61974, 61975
Solution
Ensure release valve is tightly
closed
Remedy overload condition
Ensure adequate air supply
Ensure release valve is tightly
closed
Remedy overload condition
Contact manufacturer or service
partner
Drain fluid to proper level
Clean and lubricate moving parts
Ensure proper fluid level
With ram fully retracted, remove
oil filler plug to let pressurized air
escape; reinstall oil filler plug
Ensure proper fluid level