Diode testing
7
Range
6.00 V
Overload protection: 1000 V/DC,750 V/AC, 200 A, test voltage approx. 3.3 V
Acoustic continuity test
8
Range
600.00 Ω
Overload protection: 1000 V/DC,750 V/AC, 200 A, test voltage approx. 1.2 V
Non-contact voltage measurement
9
Range
>100 - 750 V/AC
Resolution
0.001 V
Resolution
0.1 Ω < 10 Ω continuous
tone
Distance
At <10 mm: Continuous tone and LED flashes
Accuracy
0.5 - 0.8 V
Accuracy
<10 Ω continuous tone
>100 Ω (no tone)