6
Characteristic of Cooling Operation (in Cool/Auto mode)
Characteristics of Heating Operation (in Heat/Auto mode)
Starting Operation
The air conditioner automatically controls the following operation to
prevent the reduction of heating capacity and space comfort.
Defrost Operation
(Frost removal
operation for the
outdoor unit)
Hot start
‡ :KHQ WKH 212)) EXWWRQ LV SUHVVHG DJDLQ WKH DLU
FRQGLWLRQHU ZLOO VWRS RSHUDWLQJ DQG WKH 2SHUDWLRQ
ODPS ZLOO WXUQ RII
* :KHQ WKH DLU FRQGLWLRQHU LV VWRSSHG ZKLOH LQ WKH
+HDWLQJ 2SHUDWLRQ WKH IDQ ZLOO FRQWLQXH WR
operate for approximately 1 minute to remove
residual heat from the indoor unit.
Note
‡ 7R SUHYHQW ZDWHU OHDNDJH RU V\VWHP IDLOXUH GR QRW WXUQ RII WKH
SRZHU LPPHGLDWHO\ :DLW DW OHDVW  PLQXWHV IRU WKH GUDLQ SXPS WR
¿QLVK GUDLQLQJ UHVLGXDO ZDWHU IURP WKH LQGRRU XQLW
‡ :KHQ RSHUDWLQJ FRQWLQXRXVO\ DW KRUL]RQWDOO\ RU GRZQZDUG DLUÀRZ
GLUHFWLRQ DLU EORZV LQ WKH DXWRPDWLFDOO\ VHW GLUHFWLRQ IRU D SHULRG RI
WLPH WR SUHYHQW FRQGHQVDWLRQ RQ WKH KRUL]RQWDO ÀDS
7KH UHPRWH FRQWUROOHU GLVSOD\V WKH DLUÀRZ GLUHFWLRQ WKDW LV VHW
‡ ,I WKH &RROLQJ 2SHUDWLRQ LV XVHG ZKHQ WKH URRP WHPSHUDWXUH LV ORZ
frost forms on the heat exchanger of the indoor unit.
7KLV FDQ GHFUHDVH WKH FRROLQJ FDSDFLW\ ,Q WKLV FDVH WKH DLU FRQGLWLRQHU
DXWRPDWLFDOO\ VZLWFKHV WR WKH 'HIURVW 2SHUDWLRQ IRU D ZKLOH
'XULQJ WKH 'HIURVW 2SHUDWLRQ WKH ORZ DLUÀRZ UDWH RU D JHQWOH ZLQG LV
XVHG WR SUHYHQW WKH GLVFKDUJH RI PHOW ZDWHU
7KH UHPRWH FRQWUROOHU GLVSOD\V WKH DLUÀRZ UDWH WKDW LV VHW
‡ :KHQ WKH RXWGRRU DLU WHPSHUDWXUH LV KLJK LW WDNHV VRPH WLPH XQWLO WKH
room temperature reaches the set temperature.
‡ Heating Operation generally requires a longer time to reach the set
WHPSHUDWXUH FRPSDUHG ZLWK &RROLQJ 2SHUDWLRQ
It is recommended to start operating in advance by utilizing the timer.
‡ 7KH DLU FRQGLWLRQHU ZLOO DXWRPDWLFDOO\ JR LQWR 'HIURVW 2SHUDWLRQ WR SUHYHQW
frost accumulation at the outdoor unit and loss of heating capacity.
‡ 7KH LQGRRU XQLW IDQ ZLOO VWRS DQG
displayed on the remote controller.
‡ 7KH DLU FRQGLWLRQHU ZLOO UHWXUQ WR QRUPDO RSHUDWLRQ DIWHU DSSUR[LPDWHO\ 
to 8 minutes (Max 10 minutes).
‡ When the air conditioner goes into Heating Operation or Defrost
2SHUDWLRQ WKH LQGRRU XQLW IDQ ZLOO VWRS LQ RUGHU WR SUHYHQW D FROG GUDIW
,Q WKDW FDVH
'HIURVW+RW VWDUW ZLOO EH GLVSOD\HG RQ WKH
remote controller.)
'HIURVW+RW VWDUW ZLOO EH
14