Haier AD09LS1ERA Operation Manual And Installation Manual page 25

Duct type air conditioner
Hide thumbs Also See for AD09LS1ERA:
Table of Contents

Advertisement

Installation Procedure
Hose
Drain pipe size: (3/4") PVC pipe
The hose is used for adjusting the off-center and angle of the rigid PVC pipe.
Directly stretch the hose to install without making any deformation.
The soft end of the hose must be fastened with a hose clamp.
Please apply the hose on horizontal part Insulation treatment.
Wrap the hose and its clamp up to the indoor unit without any
clearance with insulating material, as shown in the figure.
Drain confirmation
During trial run, check that there is no leakage at the pipe connection part during water draining even in winter.
TURN OFF ELECTRIC POWER AT CIRCUIT BREAKER OR POWER SOURCE BEFORE MAKING ANY ELECTRIC
CONNECTIONS. GROUND CONNECTIONS MUST BE COMPLETED BEFORE MAKING LINE VOLTAGE CONNECTIONS.
Precautions for Electrical wiring
Electrical wiring work should be conducted only by authorized personnel.
Do not connect more than three wires to the terminal block. Always use round type crimped terminal lugs with insulated grip on
the ends of the wires.
Use copper conductor only.
Wiring connection
Make wiring to supply power to the outdoor unit, so that the power for the indoor unit is supplied by terminals.
WARNING
DANGER OF BODILY INJURY OR DEATH
Indoor unit
terminal block
Outdoor unit
terminal block
Subsidiary insulation
1
2
3
Y/G
1(N) 2(L) 3(C)
Y/G
Electrical wiring
Hose
Hose clamp
Insulation
Rigid PVC pipe

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents