Symbol Description; Safety Instructions; Installation - Grundfos AQpure Instructions Manual

Modular water treatment system with ce
Table of Contents

Advertisement

English (GB) Safety instructions
Original safety instructions
These safety instructions give a quick overview of the safety
precautions to be taken in connection with any work on this
product.
Observe these safety instructions during handling, installation,
operation, maintenance, service and repair of this product.
These safety instructions is a supplementary document, and all
safety instructions will appear again in the relevant sections of
the installation and operating instructions.
Keep these safety instructions at the installation site for future
reference.
These safety instructions only apply to the AQpure
Note
modular water treatment systems with CE mark that
are listed in the Declaration of conformity.
General information
Symbol
Description
This symbol indicates a danger of electric shock.
This symbol indicates a danger of burns or personal
injury from hot surface.

Safety instructions

Observe the separate supplier documents for the
Caution
components. All supplier documents are part of the
documentation package delivered with the system.
Warning
Danger of personal injury due to contact with
chemicals!
Wear the stipulated personal protective equipment
(protective clothing, gloves, goggles, etc.) when
handling chemicals!
Observe the chemical manufacturer's safety data
sheets (MSDS) and safety instructions of the used
chemicals!
Warning
Danger of personal injury due to contact with
chemicals!
If the system is installed in a confined room,
ventilation is required.
Spillages must be removed immediately.
The floor around the system must be slip-resistant.
Make sure, that parts in contact with the chemicals
are resistant to the chemicals under the specific
operating conditions!
Caution
Should you have questions regarding the material
resistance of the system for specific chemicals,
please contact Grundfos.
Warning
Sodium hypochlorite is alkaline and will cause
oxidisation and bleaching. It is corrosive and could
cause damage to skin or clothing.
Always wear chemical protective clothing and
goggles when handling chemicals!
Warning
Treat sodium hypochlorite as an alkali and keep it
away from acids, otherwise chlorine gas will be
liberated!
A warning notice detailing this must be displayed
locally!
2
The sound pressure level of the AQpure system is up
to 90 dbA.
Caution
Wear personal ear protection when working near the
AQpure system.
Warning
Death or serious injury
Danger of malfunction or damage to the product.
The AQpure system must be earthed with an earth
cable.
Equipotential bonding is installed between all
interfaces and metallic parts to prevent build-up of
static electricity.
All equipotential bonding and earthing must be
reinstalled properly after repair or maintenance.
Storage and handling
Warning
Wear the stipulated personal protective equipment
(protective clothing, gloves, safety boots)!
Observe the separate supplier documents for the
Caution
components. All supplier documents are part of the
documentation package delivered with the system.
The fibres inside the membrane can be damaged, if
Caution
the membrane is left empty for more than 2 hours.
Thoroughly inspect the packaging for damage from
Caution
transport. If any damage is identified, contact
Grundfos.

Installation

The operating company is responsible for the
preparation of the installation location according to
the following information and section:
the operating
company.
Caution
The installation itself (installation of membrane and
GAC filter, hydraulic and electrical connection etc.)
must only be done by certified service staff according
to the separate service instructions, which are
supplied to certified service staff only.
Warning
The installation must meet the local requirements
and standards for the installation of machinery
equipment.
Observe the separate supplier documents for the
Caution
components. All supplier documents are part of the
documentation package delivered with the system.
Observe the maximum floor load.
Caution
The foundation must be based on a sufficiently
bearing ground.
Obligations of

Advertisement

Table of Contents
loading

Table of Contents