Fitting and servicing the filling link
3
Fig. 4
Fitting
[1] Blanking caps
[2] Securing screws
[3] Filling link
4.2 Fitting and servicing the automatic filling link
▶ Close the isolating valves on the DHW inlet and CH return connections.
▶ Unscrew and remove the blanking plugs from the DHW inlet and CH return
connections.
▶ Ensure that the filter is positioned inside the inlet of the filling link.
▶ Assemble the filling link onto the DHW inlet and CH return connections.
▶ Ensure that the filling link is pushed in fully up to the stop tabs on both sides of the
filling link.
▶ Fit two screws and lock washers in each of the isolating valves.
▶ Open the isolating valves on the DHW inlet and CH return connections.
▶ Fit cable to auto filling link
▶ Fit cable to control as shown in appliance installation manual.
8
2
1
2
2
2
1
0010019847-001