General description

3
General description
The automatic and the manual filling link are Type CA, non-verifiable disconnectors
according to EN 14367-2005.
The filling links have a backflow prevention device and can be left permanently
1)
connected to the heating system up to category 3
heating water according to
EN 1717-2000.
1
2
3
4
5
5
0010019848-001
Fig. 2
General description
[1] Central heating return connection
[2] Domestic cold water connection
[3] Filter
[4] Filling lever
[5] Stop tabs
1) The border between category 3 and category 4 is in principle LD 50 = 200 mg/kg
body weight in reference to the EU directive 93/21 EEC dated April 27th, 1993.