Download Print this page

Milk Level Control - La Cimbali M5 Series Manual

Advertisement

English
With the machine "ON" and the refrigerator unit at working temperature:
A - Open door (51).
B - Remove the container caps.
C - Insert the two refrigerated milk containers.
D - Insert the cappuccino machine tubes (1) into the container slots.
E - Place the containers inside the machine and close the door (51).
N.B. For greater efficiency we recommend that door (51) remain
open for a short a time as possible.
Correct milk storage temperature
The correct milk storage temperature is approximately 5°C (41°F).
This temperature can be controlled through the thermometer (58)
situated on the refrigerator door.
Milk storage temperature not correct

When the temperature exceeds 5°C (41°F) and remains
at this value for a prolonged period of time, the storage
temperature is not correct. Remove the milk containers and place them
in the refrigerator. Wait until the temperature returns to approximately
5°C (41°F) before replacing the containers in the machine.
If the problem persists, call the authorized servicing department.
Refrigerator unit temperature adjustment
To adjust the refrigerator unit temperature, lift the command panel and
turn the thermostat knob (56).
- When the knob is turned clockwise, the milk storage temperature is
decreased.
- When the knob is turned anti-clockwise, the milk storage temperatu-
re is increased.
When the message "no milk" is displayed (5), this indicates that one
(or both) of the containers is empty. The container must be refilled.
If the "no milk" message on the display (5) is not displayed

and there is no milk in one (or both) of the containers, this
may be due to a malfunction of the photo-electric cells
(57).
It is recommended that the area around the photo-electric cells (57) be
carefully cleaned with a cloth. Ensure that the malfunction does not
reoccur.
If the malfunction persists even after the photo-electric cells (57) have
been cleaned, call the authorized servicing department.
Use
Milk Temperature Control
56

Milk Level Control

57
-
+
58
English

Advertisement

loading

This manual is also suitable for:

M52 station dolcevita