WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK, UNPLUG BEFORE

TROUBLESHOOTING.

PROBLEM
No power supply.
The wet/dry
Faulty power cord.
vacuum will not
operate.
Collection tank is full.
Switch in the wrong position.
The reusable cloth filter is missing
or damaged.
The dust comes
Vacuum has been used to collect
out from the
fine dust, such as drywall dust,
motor cover.
fireplace soot, or ash, without a fine
dust filter equipped.
There are blockages in the nozzle,
Reduced
hose, or the collection tank inlets.
efficiency and
motor/speed
The reusable cloth filter is clogged
vibration.
by fine dust.
TROUBLESHOOTING
POSSIBLE CAUSE
Check the power supply, cord,
breakers, and fuses.
Unplug and check the power cord.
If damaged, have it repaired by a
professional.
Empty the collection tank.
Press the ON 'I' button on the power
head.
Attach or replace the reusable cloth
filter.
Remove the reusable cloth filter and
install the appropriate fine dust filter.
Unplug and check nozzle, hose and
collection tank inlets for blockages.
Take off the filter and clean it or
install a new reusable cloth filter.