Removal of Humidifier Unit
Step
5
Disconnect the 4 relay
connectors.
Disconnect the
6
connector for humidifier
fan motor.
Remove the 4 screws
7
of the humidifier unit
and lift it up to remove.
4
Procedure
Relay connectors
Humidifier fan motor
Mounting plate
Do not pull the harnesses
from the outdoor unit
strongly so as not to loose
the hook of the mounting
plate.
(See the illustration below
on this page for the
mounting plate.)
(R9886)
Be sure to wait for 10
minutes or more after
turning off the power supply
before disconnecting the
connectors.
Pull out the connector while
pushing up the hook on the
bottom side.
(R9887)
}
<From the back side>
Humidifier unit
Hook
When lifting up the
humidifier unit, be careful
not to pull the relay
harnesses forcibly.
When reassembling the
(R10555)
humidifier unit, make sure
the mounting plate is
hooked and do not forget to
connect the relay
connectors.