Electrical connections

L-N
Power supply 230V (a.c.) 50/60 Hz
U-V-W 230V A.C. gearmotor
+ E D Encoder (E=black, D=red)
F-FA
Opening endstop
F-FC
Closing endstop
10-11 Terminals for powering 24V (a.c.) accessories
W-E1 Flashing light (socket rating: 230V - 25W max.)
EX-E1 Cycle lamp: (contact rating: 230V – 60W max.)
10-5
Open gate indicator-light (socket rating: 24V - 3W max.)
2-CX..CY Re-open during closing" (N.C.) socket, re-close during
opening, partial stop or stand-by Obstacle
Electrical connection to operate the photocells' safety test
(DOC)
The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
2-C7..C8 Re-open during closing" (N.C.) socket, re-close during
opening, partial stop or stand-by Obstacle (sensitive edges)
1-2
Stop button (N.C. contact)
2-3
Opening button (N.O. contact)
2-4
Closing button (N.O. contact)
2-3P Partial opening button (N.O.)
2-7
Keyswitch and/or commands button (N.O.)
2-A-B "NET address" function is set when connecting two paired
operators
Connection of antenna
- The transmitter and receiver, must be connected as shown in
the diagram;
- from the functions menu, select "safety tests" and select
either CX or CY input/s to activate the test.
(DIR)