Motor Jog; Automatic Operation - Champion Simplex Operation & Service Manual

Table of Contents

Advertisement

MCGUIRE AIR COMPRESSORS INC
3.2

Motor Jog

Prior to automatic operation of the unit, each motor in the system MUST be jogged to ensure proper
compressor rotation direction.
IMPORTANT: Extended rotation in the incorrect direction can cause catastrophic damage to the
compressor.
If equipped with selector switch, jog motor using the TEST position. Verify correct rotation
direction.
If equipped with HOA (Hydrovane only), jog motor using the HAND position. Verify correct
rotation direction.
If not equipped with selector switch, jog motor using main disconnect.
3.3

Automatic Operation

Automatic starting of the compressor can cause injury or death
After the proper pump rotation has been verified:
If equipped with selector switch, place in the AUTO position to start the automatic sequencing
of the compressor.
If not equipped with selector switch, main disconnect can be closed and automatic sequencing
will be provided by the pressure switch.
Simplex Control Panel
Operation & Service
MCGUIRE AIR COMPRESSORS INC
7
1-888-229-9999
CQF3475 v.02
August 06, 2019
1-888-229-9999