Drawing No.
Malfunctioned
component
Unit
Symptom
description
Cooking LED
lights up
Cooking LED
does not light up
LED does not
operate at all
Indicates
Does not cook
"H01" on LCD.
Indicates
"H02" on LCD.
Indicates
"H06" on LCD.
Indicates
"H05" on LCD.
Cannot cook rice correctly (stops
early or cooking is uneven, etc.)
Rice on bottom of the inner pan
is scorched
Keep Warm temperature is high
(over 78 C)
Keep Warm temperature is low
(below 68 C)
Does not
Keep Warm
keep warm
LED lights up
Droplets fall onto the surface of rice
The surface of rice dries up
The bottom of warm jar
melts and fires
15 23 44 48 48 54 61 6 22
7
Refer to page 9,10 when
the malfunctioned parts
are supposed to be on
the P.C.B..
If the fuse melts, check and remove
the cause firstly, then replace the
malfunctioned part.
This may occur due to user's
improper measurement or
insufficient loosening of rice.
Check that there is on dirt or foreign
substances stuck to the surface of
the pan sensor.
This may occur by unplugging or
insufficient loosening of rice.
This may occur when the lid is kept open
for a long time, insufficient loosening of
rice or falling of Keep Warm pin.
SR-MG102, 182