Tools Required; Surface Mount; Maintenance - Cooper Lighting Streetworks Valet LED Installation Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

Installation Instructions – Valet LED

Tools required

Hardware to secure to ceiling structure [not supplied],
Phillips head screwdriver, electrical wiring tools, drill.

Surface Mount

1.
Loosen four screws on front of light fixture. Remove
Cover and set aside.
2.
Remove LightBAR assembly from fixture by inserting a
screwdriver and carefully lifting the LightBAR assembly.
This assembly is secured to the fixture by a safety
lanyard to prevent damage/injury. Do not remove this
lanyard.
3.
Drill through the top side of the casting. See Figure 5.
For the suggested drill pattern to avoid damage to any
internal components to the fixture. Only drill from the
inside of the fixture.
4.
Feed supply wires through the 3/4" NPT opening on
top of the fixture.
5.
Connect supply wires to appropriate fixture leads with
wire nuts inside the housing:
a) Supply side ground wire to green fixture lead.
b) Supply side neutral wire to white fixture lead.
c) Supply side line voltage wire to black fixture lead.
6.
Secure housing to mounting surface using hardware
[not supplied].
7 .
Replace LightBAR assembly and cover back onto the
housing and tighten the four screws. Make certain no
wiring is trapped between the LightBAR assembly and
the side of the housing to avoid damage/pinched wires.
8.
The fixture is now ready to energize.
For wet location usage, use appropriate outdoor
N
ote:
caulking compound [latex, silicone, etc.] to seal
the joint between the die-cast housing and the
mounting surface to avoid water entry through the
wire opening in the housing. This particular mounting
configuration is rated for ambient usage of 25°C.
4
Cooper Lighting Solutions
IB506019EN
Installation instructions
Bi-Level Switching [If Equipped]
For Bi-level switching, the input leads to the fixture will be
independently labeled to indicate dimming preferences as
appropriate [as defined by the order requirements]. Two
Separate supply lines of line voltage, neutral and ground
must be provided to the fixture to enable the bi-level
switching functionality of the fixture.

MAINTENANCE

A regular maintenance schedule should be followed to
retain optimal light output and thermal performance. Optical
lens cleaning should be performed with a clean dry cloth to
remove any dust or other contaminants. Additional cleaning
can be performed with non-abrasive acrylic cleansing
solution.
Drill Point #1
Figure 5.
4"
Drill Point #2
Supply Wire
Entry Point
Drill Point #3